SAINT PETERSBURG, FL —
OSHA Inspection: BERGERON FRAMING, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of BERGERON FRAMING, INC. in 10601 GANDY BOULEVARD NORTH, SAINT PETERSBURG, FL 33702 (NAICS 238130). OSHA activity number 341374098.
Where did this inspection happen?
- Establishment
- BERGERON FRAMING, INC.
- Site address
- 10601 GANDY BOULEVARD NORTH
- City
- SAINT PETERSBURG
- State
- FL
- ZIP
- 33702
- Mailing
- 125 BAYWOOD AVENUE, LONGWOOD, FL 32750
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1903.19 D01
- Issued
- Abate by
- Penalty
- Initial $1000.00 · Current $1000.00
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. On or about July 6, 2016, for the inspection site on 10601 Gandy Boulevard North in Saint Petersburg, FL: a) Abatement documentation was not provided for citation 1 item 1a, and b) Abatement documentaion was not provided for citaion 1 item 1b.
Recent events (1)
- — Z (O) $1000
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: (a) At the job site, employees erecting wood trusses exposed to a fall hazard of approximately 40 feet. Feasible conventional fall protection methods such as but no limited to scissor lifts or booms, bracket scaffolding attached to the inside or outside of the exterior walls, spreader bars attached to roof trusses, work practices (completing truss sections, erecting and sheeting a series of trusses on the ground and then lifting the unit into place with a crane) to minimize the risk of falls while employees were erecting wood trusses and exposed to fall hazard of approximately 40 feet on or about were not provided as observed on or about 01/21/2016.
Recent events (2)
- — I (O) $2800
- — Z (S) $2800
1926.502 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(k)(6): The fall protection plan did not include a written discussion of other measures that will be taken to reduce or eliminate the fall hazard for workers who cannot be provided with protection from the conventional fall protection systems. For example, the employer did not discuss the extent to which scaffolds, ladders, or vehicle mounted work platforms can be used to provide a safer working surface and thereby reduce the hazard of falling. a) At the job site, the fall protection plan did not consider other alternative fall protection systems criteria and practices such as but not limited to the use scissor lifts or booms, bracket scaffolding attached to the inside or outside of the exterior walls, spreader bars attached to roof trusses, work practices (completing truss sections, erecting and sheeting a series of trusses on the ground and then lifting the unit into place with a crane) to minimize the risk of falls while employees were erecting wood trusses and exposed to fall hazard of approximately 40 feet, on or about 01/21/2016.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at BERGERON FRAMING, INC.
TEMPLE TERRACE, FL—2023-05-03 00:00:00
BERGERON FRAMING, INC.
ORLANDO, FL—2019-04-18 00:00:00
BERGERON FRAMING, INC.
RIVERVIEW, FL—2017-08-16 00:00:00
BERGERON FRAMING, INC.
WESLEY CHAPEL, FL—2017-08-14 00:00:00
BERGERON FRAMING, INC.
JACKSONVILLE, FL—2017-06-14 00:00:00
BERGERON FRAMING, INC.
View BERGERON FRAMING, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in FL
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
MELBOURNE, FL—2026-07-13
OMNIPOTENT BRANDS, LLC
QUINCY, FL—2026-07-13
WALMART
INDIAN ROCKS BEACH, FL—2026-07-10
UNKNOWN CONTRACTOR
CLEARWATER, FL—2026-07-10
ROOFTECH ROOFING & WATERPROOFING INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341374098.