CASTLE ROCK, CO —
OSHA Inspection: DOUGLAS COUNTY DIESEL
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DOUGLAS COUNTY DIESEL in 1160 CAPRICE DRIVE, CASTLE ROCK, CO 80109 (NAICS 811111). OSHA activity number 341397321.
Where did this inspection happen?
- Establishment
- DOUGLAS COUNTY DIESEL
- Site address
- 1160 CAPRICE DRIVE
- City
- CASTLE ROCK
- State
- CO
- ZIP
- 80109
- Mailing
- 1160 CAPRICE DRIVE, CASTLE ROCK, CO 80109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 12
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.252 A01 I
- Issued
- Abate by
- Penalty
- Initial $2040.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place: a. On or about April 7, 2016 and at times prior, employees were exposed to fire hazards from flammable liquids inside several containers located at the welding area. The flammable liquids were not moved to a safer place away from the welding area.
Recent events (2)
- — I (S) $1020
- — Z (S) $2040
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a. On or about April 7, 2016 and at times prior, employees were exposed to fire hazards from oxygen cylinders that were stored together fuel-gas cylinders located at the welding area. The stored oxygen cylinders were not separated from fuel-gas cylinders at least 20 feet away.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $340.00 · Current $170.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a. On or about April 7, 2016 and at times prior, the floor located at the east side shop area was full of dirt, grease, and trash. The employer did not kept the floor clean and orderly.
Recent events (2)
- — I (O) $170
- — Z (O) $340
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $340.00 · Current $170.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a. On or about April 7, 2016 and at times prior, employees were required to use an exit door located at the north side of the shop area in the event of an emergency. The exit door was not provided with an exit sign.
Recent events (2)
- — I (O) $170
- — Z (O) $340
1910.304 F01 IV
- Issued
- Abate by
- Penalty
- Initial $340.00 · Current $170.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: a. On or about April 6, 2016 and at times prior, an electrical switch box and circuit breaker panel located at the west side of the shop were blocked with shop equipment and vehicle parts. The electrical switch panel and switchboard were not readily accessible to each employee.
Recent events (2)
- — I (O) $170
- — Z (O) $340
More inspections in this industry (NAICS 811111)
LONGVIEW, WA—2026-07-09
WA317992006 - LONGVIEW AUTO REPAIR LLC
HOUGHTON LAKE, MI—2026-07-08
WILSON'S AUTOMOTIVE
KELSO, WA—2026-07-08
WA317991989 - THOMAS TRANSMISSIONS LLC
BURTON, MI—2026-07-07
AMERICA'S MOST WANTED 4X4
FISHERS, IN—2026-07-07
PEP BOYS AUTO SERVICE & TIRES
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source