WESTLAKE, LA —
OSHA Inspection: PPG INDUSTRIES
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PPG INDUSTRIES in 3150 PETE MANENA RD, WESTLAKE, LA 70669 (NAICS 325510). OSHA activity number 341410314.
Where did this inspection happen?
- Establishment
- PPG INDUSTRIES
- Site address
- 3150 PETE MANENA RD
- City
- WESTLAKE
- State
- LA
- ZIP
- 70669
- Mailing
- 3150 PETE MANENA RD, WESTLAKE, LA 70669
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 214
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $12471.00 · Current $0.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the potential hazard of fire and explosion. On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, the employer did not ensure that piping safety relief valves (SRVs) were inspected as required.
Recent events (3)
- — F (S) $0
- — C (S) $12471
- — Z (S) $12471
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $12471.00 · Current $12471.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a burn hazard: On or about April 14, 2016, at the AP area, the employer allowed employee(s) to access a leaking operating hot water tank with a water temperature of over 120F to take samples on the other side of a valve.
Recent events (2)
- — C (S) $12471
- — Z (S) $12471
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $7126.00 · Current $7126.00
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition: a) The employer did not ensure that passageways in the Dryer building were kept clean and orderly. This violation occurred on or about April 11, 2014 when employees in the Dryer building were required to process amorphous silica and large amounts of silica were on the floors and equipment.
Recent events (2)
- — C (S) $7126
- — Z (S) $7126
1910.23 E03 IV
- Issued
- Abate by
- Penalty
- Initial $12471.00 · Current $12471.00
General-duty citation text
29 CFR 1910.23(e)(3)(iv): The anchoring of posts and framing of members for railings of all types were not of such construction that the completed structure shall be capable of withstanding a load of at least 200 pounds applied in any direction at any point on the top rail. On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, employees were exiting the dryer building and using the stairway which have guard rails that have deteriorated. Or, in the alternative; OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fall: On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, employees were exiting the dryer building and using the stairway which have guard rails that have deteriorated.
Recent events (2)
- — C (S) $12471
- — Z (S) $12471
1910.134 H02 I
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $8908.00
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, the employer did not ensure that SCBA respirators used by employees for emergencies were properly stored in cabinets to protect them from silica dust.
Recent events (2)
- — C (S) $8908
- — Z (S) $8908
1910.146 C05 II C
- Issued
- Abate by
- Penalty
- Initial $12471.00 · Current $12471.00
General-duty citation text
29 CFR 1910.146(c)(5)(ii)(C): Employees entered into permit spaces that met the conditions set forth in 29 CFR 1910.146(c)(5)(i) but before an employee entered the space, the internal atmosphere was not tested with a calibrated direct-reading instrument: On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, the employer did not conduct air monitoring before employees were required to enter a confined space to conduct maintenance on equipment located in the space.
Recent events (2)
- — C (S) $12471
- — Z (S) $12471
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $8908.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer did not ensure that periodic inspections of the energy control procedures were conducted at least annually to ensure that the procedures and the requirement of this standard were being followed by the employees.
Recent events (2)
- — C (S) $8908
- — Z (S) $8908
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $8908.00
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about 04/14/2016, at 3150 Pete Manena Road, Westlake, LA, the employer did not ensure that a plumbed eyewash equipment was capable of delivering flushing fluid to the employees eyes on the LPSD (Large Particle Spray Dryer) platform.
Recent events (2)
- — C (S) $8908
- — Z (S) $8908
1910.219 E03 I
- Issued
- Abate by
- Penalty
- Initial $8908.00 · Current $8908.00
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: On or about April 11, 2016, located in the dryer building area, guards were missing on a transfer blower on the main power drive belt and pulley.
Recent events (2)
- — C (S) $8908
- — Z (S) $8908
1910.37 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision can see along the exit route: On or about 04/11/2016, at 3150 Pete Manena Road, Westlake, LA, employees were working in an administration building with exit signs not adequately illuminated.
Recent events (2)
- — C (O) $0
- — Z (O) $0
1910.305 B02 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about April 11, 2016, the employer did not ensure that the junction box located in the Dryer building had a cover installed exposing employees to the hazard of electrical shock.
Recent events (2)
- — C (O) $0
- — Z (O) $0
More inspections at PPG INDUSTRIES
CIRCLEVILLE, OH—2020-10-02 00:00:00
PPG INDUSTRIES
SPRINGDALE, PA—2019-03-28 00:00:00
PPG INDUSTRIES
SPRINGFIELD, IL—2017-03-20 00:00:00
PPG INDUSTRIES
WICHITA FALLS, TX—2015-10-07 00:00:00
PPG INDUSTRIES
WESTLAKE, LA—2014-08-07 00:00:00
PPG INDUSTRIES
View PPG INDUSTRIES's full OSHA safety record →
More inspections in this industry (NAICS 325510)
HEALDSBURG, CA—2026-07-08
RUPERT GIBBON & SPIDER, INC.
ROCKLEDGE, FL—2026-06-24
RICHARD'S PAINT MANUFACTURING CO
ROCHESTER, PA—2026-06-18
THE SHERWIN-WILLIAMS COMPANY
AUBURN, CA—2026-06-15
PRESERVA PRODUCTS LTD
FAIRLESS HILLS, PA—2026-06-09
SUDARSHAN FAIRLESS HILLS MANUFACTURING
More inspections in LA
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
MORGAN CITY, LA—2026-07-10
G4 SERVICES LLC
PIERRE PART, LA—2026-07-08
DOLLAR GENERAL
LAKE CHARLES, LA—2026-07-01
GULF COAST FORENSIC SOLUTIONS
BATON ROUGE, LA—2026-06-26
TRAFFIC CONTROL PRODUCTS CO. OF LOUISIANA, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341410314.