Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN IRON INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of AMERICAN IRON INC. in 55 EAGLE STREET, ALBANY, NY 12211 (NAICS 238120). OSHA activity number 341414407.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Iron INC. — free Get an email when a new federal OSHA severe-injury report for American Iron INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AMERICAN IRON INC.
Site address
55 EAGLE STREET
City
ALBANY
State
NY
ZIP
12211
Mailing
2323 2ND AVENUE, SCHENECTADY, NY 12303
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
50
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 5 1 instance 50 exposed
Issued
May 24, 2016
Abate by
Jun 6, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, was not visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective was not repaired.    a) Worksite - on or about April 12, 2016, along the corridor area of the "L1" level, an extension cord that was plugged in and supplying power, had a missing ground prong. In the event of a ground fault the power tools could become energized and shock the user.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1926.501 B01

Serious Gravity 5 1 instance 50 exposed
Issued
May 24, 2016
Abate by
Jun 2, 2016
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1926.501(b)(1): Employees on walking/working surfaces with an unprotected side and/or edge which is 6 feet or more above a lower level were not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:    a) Worksite - on or about April 12, 2016 - on the "L1" level, fall protection which consisted of steel cables installed on building columns, was incomplete. The middle cable was removed, exposing workers to 15 foot fall to a lower level.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

View American Iron INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341414407.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.