SYRACUSE, NY —
OSHA Inspection: HORN COMPANIES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HORN COMPANIES, LLC in 220 EAST HERALD AVE, SYRACUSE, NY 13202 (NAICS 236220). OSHA activity number 341418960.
Where did this inspection happen?
- Establishment
- HORN COMPANIES, LLC
- Site address
- 220 EAST HERALD AVE
- City
- SYRACUSE
- State
- NY
- ZIP
- 13202
- Mailing
- 6194 THOMPSON ROAD, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 11
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B14
- Issued
- Abate by
- Penalty
- Initial $3563.00 · Current $2672.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) 220 East Herald Ave. Syracuse, NY, 3rd floor east window area. On or about 4/20/16: Window openings were not properly guarded to prevent falls of three stories to the ground below.
Recent events (2)
- — I (S) $2672.25
- — Z (S) $3563
1926.502 B03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge. a) 220 East Herald Ave, Syracuse NY, 2nd floor window area. On or about4/20/16: Plywood was used at a guardrail system that was not substantial enough to withstand 200 pounds of either outward or downward pressure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 236220)
ROCHESTER, NH—2026-07-17 00:00:00
STAR CONSTRUCTION SVS INC
WHITESTOWN, IN—2026-07-17 00:00:00
CENTRAL WELDING INC
MOUNTAIN LAKES, NJ—2026-07-17 00:00:00
JOHN CARUSO BUILDERS LLC
FAIRFAX, VA—2026-07-17 00:00:00
RYCON CONSTRUCTION, INC.
SHAWNEE, KS—2026-07-16 00:00:00
BRATTON BROTHERS CONTRACTING INC
More inspections in NY
LIBERTY, NY—2026-07-17 00:00:00
SULLIVAN COUNTY CARE CENTER AT SUNSET LAKE
NEW YORK, NY—2026-07-17 00:00:00
VERGARA ELECTRICAL LLC
ONEONTA, NY—2026-07-17 00:00:00
APPLE CONVERTING, INC.
SYRACUSE, NY—2026-07-17 00:00:00
NAMICELA HOME SOLUTIONS INC
SYRACUSE, NY—2026-07-17 00:00:00
CRANESVILLE BLOCK CO., INC.
Source