HENAGAR, AL —
OSHA Inspection: POLYMER INDUSTRIES, L.L.P.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of POLYMER INDUSTRIES, L.L.P. in 10526 ALABAMA HIGHWAY 40, HENAGAR, AL 35978 (NAICS 326130). OSHA activity number 341494573.
Where did this inspection happen?
- Establishment
- POLYMER INDUSTRIES, L.L.P.
- Site address
- 10526 ALABAMA HIGHWAY 40
- City
- HENAGAR
- State
- AL
- ZIP
- 35978
- Mailing
- 10526 ALABAMA HIGHWAY 40 P.O. BOX 32, HENAGAR, AL 35978
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326130
- Employees
- 220
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $2295.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) On or about 05/18/2016 - Maintenance department, employees handling Poly HP-2 lubricating grease were not provided adequate personal protective equipment while greasing machinery such as impervious gloves and clothing.
Recent events (2)
- — I (S) $1500
- — Z (S) $2295
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4590.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 05/18/2016 - Plant, no procedures had been established for employees that perform servicing and maintenance activities on machinery such as, but no limited to, the Hendrick saw and the Pulverizer no. 1.
Recent events (2)
- — I (S) $3000
- — Z (S) $4590
1910.333 B02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: a) On or about 05/18/2016 - Plant, no procedures had been documented, developed, or utilized for employees performing electrical maintenance on 110, 220, and 480 VAC electrical panels.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 III A
- Issued
- Abate by
- Penalty
- Initial $3060.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the specific operations: a) On or about 05/18/2016 - Maintenance department, authorized lockout and tagout employees were not retrained after moving from production to maintenance.
Recent events (2)
- — I (S) $2000
- — Z (S) $3060
1910.333 A
- Issued
- Abate by
- Penalty
- Initial $6300.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a) On or about 05/18/2016 - Maintenance, safety-related work practices were not provided to employees working on energized and deenergized 110, 220, and 480 volt electrical panels.
Recent events (2)
- — I (S) $4500
- — Z (S) $6300
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) On or about 05/18/2016 - Maintenance department, a hazard communication program had not been developed and implemented for employees handling chemicals such as, but not limited to, Zeniplex EP 2 and Poly HP-2 lubricating greases.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326130)
DANVILLE, KY—2026-07-09
69313 - TRANSNAV TECHNOLOGIES INC
CINCINNATI, OH—2026-06-30
FORMICA CORPORATION
ERIE, PA—2026-06-24
HAYSITE REINFORCED PLASTICS, LLC
OAK CREEK, WI—2026-05-19
BAY VIEW INDUSTRIES, INC.
SOUTH EUCLID, OH—2026-05-06
ROECHLING CORP.
More inspections in AL
CLANTON, AL—2026-07-13
UBIQUE TECHNOLOGIES, INC.
IRONDALE, AL—2026-07-13
FATHER NATURE LANDSCAPES OF BIRMINGHAM, INC.
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
CULLMAN, AL—2026-07-09
ALFREDO PICHARDO BLANCO
MOBILE, AL—2026-07-09
FLEXICREW TECHNICAL, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341494573.