1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: NORTHTEC, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NORTHTEC, LLC in 200 CROSSINGS DR., BRISTOL, PA 19007 (NAICS 493110). OSHA activity number 341502003.

Watch Northtec, LLC — free Get an email when a new federal OSHA severe-injury report for Northtec, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
NORTHTEC, LLC
Site address
200 CROSSINGS DR.
City
BRISTOL
State
PA
ZIP
19007
Mailing
300 CROSSINGS DR., BRISTOL, PA 19007
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
200
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $6300.00 · Current $3150.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control:    a) PADC2, Sortation Department, Dunnage Area, Stations 305/306 - on or about May 21, 2016, the employer did not train each employee unjamming paper in the Sealed Air PackTiger paper cushioning systems in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.
Recent events (2)
  • — I (O) $3150
  • — Z (S) $6300

1910.147 D03

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  a) PADC2, Sortation Department, Dunnage Area, Stations 305/306 - on or about May 21, 2016, employees unjammed paper in the Sealed Air PackTiger paper cushioning systems, reaching into the chute opening and pulling paper away from the cutting blade; the employer failed to ensure the control of energy by use of unplugging the cord and plug, exposing employees to caught-in hazards.