Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOUR SEASONS SOLAR PRODUCTS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FOUR SEASONS SOLAR PRODUCTS, LLC in 5005 VETERANS MEMORIAL HIGHWAY, HOLBROOK, NY 11741 (NAICS 332321). OSHA activity number 341826139.

Watch Four Seasons Solar Products, LLC — free Get an email when a new federal OSHA severe-injury report for Four Seasons Solar Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
5005 VETERANS MEMORIAL HIGHWAY
City
HOLBROOK
State
NY
ZIP
11741
Mailing
5005 VETERANS MEMORIAL HIGHWAY, HOLBROOK, NY 11741
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
150
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $11408.00 · Current $9126.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) Worksite, Window Department: Employees authorized to perform cleaning, maintenance, and repair work on approximately 16 punch presses were not provided with energy control procedures; on or about 10/7/16.       b) Worksite, Door Department: Employees authorized to perform cleaning, maintenance, and repair work on approximately 8 hydraulic presses were not provided with energy control procedures; on or about 10/7/16.     Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $9126
  • — Z (S) $11408

1910.147 C07 I

Serious Gravity 10 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $11408.00 · Current $9126.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:      a) Worksite, Window Department: Employees authorized to perform cleaning, maintenance, and repair work on approximately 16 punch presses were not provided with training on utilizing energy control procedures; on or about 10/7/16.       b) Worksite, Door Department: Employees authorized to perform cleaning, maintenance, and repair work on approximately 8 hydraulic presses were not provided with training on utilizing energy control procedures; on or about 10/7/16.     Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $9126
  • — Z (S) $11408

1910.147 C07 I B

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:    a) Worksite, Window Department: Employees working in proximity to equipment necessitating maintenance work were not provided with training on the purpose and use of the energy control procedure; on or about 10/7/16.      b) Worksite, Door Department: Employees working in proximity to equipment necessitating maintenance work were not provided with training on the purpose and use of the energy control procedure; on or about 10/7/16.      Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 I

Serious Gravity 5 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $8149.00 · Current $6524.00 Reduced
29 CFR 1910.178(l)(4)(i): Refresher training, including an evaluation of the effectiveness of that training, was not conducted as required by paragraph (l)(4)(ii) to ensure that the operator has the knowledge and skills needed to operate the powered industrial truck safely.    a) Worksite, Warehouse/Production Floor: Employees authorized to operate forklifts had not received training and evaluation in the safe operation of powered industrial trucks in over at least three years; on or about 10/7/16.     Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6523.5
  • — Z (S) $8149

1910.178 P01

Serious Gravity 5 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $8149.00 · Current $6524.00 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):    a) Worksite, Warehouse/Production Floor: Employees were authorized to use Combilist Forklift (Asset #1301) with a cracked front cab enclosure, obscuring operator vision; on or about 10/7/16.    Note:  The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Recent events (2)
  • — I (S) $6523.5
  • — Z (S) $8149

1910.212 A03 II

Serious Gravity 10 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $11408.00 · Current $9126.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Worksite, Hardware Department: Employees were authorized to operate Delta Unisaw, Asset #1231, to cut aluminum parts. The machinery was not equipped with an effective point of operation guard; on or about 10/6/16.     b) Worksite, Fixture Department: Employees were authorized to operate Table Saw, Asset #1204, to cut foam pieces. The machinery was not equipped with a point of operation guard; on or about 10/7/16.     Note:  In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.