On , OSHA opened a complaint safety inspection of BIG SKY TIRE RAMA in 4501 10TH AVE SOUTH, GREAT FALLS, MT 59405 (NAICS 441320). OSHA activity number 341845469.

Watch BIG SKY Tire Rama — free Get an email when a new federal OSHA severe-injury report for BIG SKY Tire Rama is published. One employer, no account, unsubscribe in one click.
Establishment
BIG SKY TIRE RAMA
Site address
4501 10TH AVE SOUTH
City
GREAT FALLS
State
MT
ZIP
59405
Mailing
4501 10TH AVE SOUTH, GREAT FALLS, MT 59405
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441320
Employees
13
Ownership type
A

7 citations on file for this inspection.

1910.212 A01

Other-than-serious 2 instances 13 exposed
Issued
Abate by
Penalty
Initial $2423.00 · Current $1454.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    A)  East Wall:  On or about October 18, 2016, and at times prior, employees were exposed to struck by hazards while working in and around the unguarded Continental 30 ton hydraulic press.    B)  South Wall:  On or about October 18, 2016, and at times prior, employees were exposed to caught in hazards while using the unguarded Ammco brake lathe.
Recent events (2)
  • — I (O) $1453.8
  • — Z (S) $2423

1910.215 A04

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $1817.00 · Current $1090.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch    A)  Northeast Wall:  On or about October 18, 2016, and at times prior, employees were exposed to caught in hazards while using a work rest adjusted to approximately 3/8 of an inch.
Recent events (2)
  • — I (O) $1090.2
  • — Z (S) $1817

1910.215 B09

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    A)  North Wall:  On or about October 28, 2016, and at times prior, employees were exposed to being struck by pieces of the abrasive wheel in the event it fractured.  The tongue guard was adjusted to 7/8 of an inch.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 I

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $1818.00 · Current $1091.00 Reduced
29 CFR 1910.303(g)(1)(i): Work space was less than 30 inches wide in front of electric equipment operating at 600 volts, nominal, or less:    A)  North Wall Tire Shop:  On October 18, 2016, and at times prior, employees were exposed to the hazards associated with not being able to de-energize equipment in the event of an emergency.
Recent events (2)
  • — I (O) $1090.8
  • — Z (S) $1818

1910.305 G01 IV A

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    A)  North Wall Mechanics Shop:  On or about October 18, 2016, and at times prior, employees were exposed to fire hazards associated with using a flexible extension cord as permanent fixed wiring.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 B02

Other-than-serious 2 instances 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    A)  Employee Break Room South Wall:  On October 18, 2016, and at times prior, employees were exposed to electrical shock hazards associated with not having a faceplate on a wall outlet.    B)  Employee Break Room East Wall:  On October 18, 2016, and at time prior, employees were exposed to electrical shock hazards associated with not having a faceplate on a light switch.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.305 G02 III

Other-than-serious 1 instance 13 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:    A)  South Wall Mechanics Shop:  On or about October 18, 2016, and at times prior, employees were exposed to shock hazards associated with a strain pull of a flexible cord powering an auto lift.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0