Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: LINCOLN BUILDERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LINCOLN BUILDERS, INC. in 65556 CENTER POINT BLVD., LACOMBE, LA 70445 (NAICS 236220). OSHA activity number 341881092.

Watch Lincoln Builders, INC. — free Get an email when a new federal OSHA severe-injury report for Lincoln Builders, INC. is published. One employer, no account, unsubscribe in one click.
Site address
65556 CENTER POINT BLVD.
City
LACOMBE
State
LA
ZIP
70445
Mailing
11567 MERCANTILE DRIVE, BATON ROUGE, LA 70809
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.350 A09

Serious Gravity 1 1 instance 24 exposed
Issued
Penalty
Initial $3680.00 · Current $2208.00 Reduced
29 CFR 1926.350(a)(9): Compressed gas cylinder(s) were not secured in an upright position).  On or about 10/26/16 near the first floor northwest classroom; the employer allowed employees to store compressed oxygen and acetylene gas cylinders without securing them from falling; thus exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $2208
  • — Z (S) $3680

1926.350 A10

Serious Gravity 1 1 instance 24 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease),   On or about 10/26/16 near the first floor northwest classroom; the employer allowed employees to store compressed oxygen and acetylene gas cylinders next to each other without a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.150 C01 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof.  On or about 10/26/16 on the west side of the building; the employer allowed employees to work in an area exceeding 3000 square feet with having a fire extinguisher nearby; thus exposing employees to the delay in extinguishing a fire.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View LINCOLN BUILDERS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341881092.