Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEYER STEEL DRUM, INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of MEYER STEEL DRUM, INC. in 2000 S. KILBOURN AVE., CHICAGO, IL 60623 (NAICS 332439). OSHA activity number 342233939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Meyer Steel Drum, INC. — free Get an email when a new federal OSHA severe-injury report for Meyer Steel Drum, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2000 S. KILBOURN AVE.
City
CHICAGO
State
IL
ZIP
60623
Mailing
2000 S. KILBOURN AVE., CHICAGO, IL 60623
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332439
Employees
66
Ownership type
A

6 citations on file for this inspection.

1910.217 C02 I D

Serious Gravity 5 2 instances 6 exposed
Issued
Jul 25, 2017
Abate by
Aug 4, 2017
Penalty
Initial $8,963 · Current $3,137 Reduced
29 CFR 1910.217(c)(2)(i)(d): Point of operation guard(s) on mechanical power press(es) did not utilized fasteners not readily removable by the operator, so as to create minimize the possibility of misuse or removal of essential parts:    a.  On or about April 6, 2017, on the L&J presses, the point of operation guards that are installed had fasteners (wing nuts and pins) that are readily removable by the operator, thereby exposing the employees to amputation hazards.
Recent events (2)
  • — I (S) $3137.05
  • — Z (S) $8963

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2017
Abate by
Jul 31, 2017
Penalty
Initial $8,963 · Current $3,137 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).    a. On or about April 6, 2017, in the coil room, the guard that covered the belt and pulley on the Dayton Speedaire air compressor was not installed, thereby exposing employees to the hazards associated with moving machine parts.
Recent events (2)
  • — I (S) $3137.05
  • — Z (S) $8963

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 25, 2017
Abate by
Jul 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  a. On or about April 6, 2017, in the coil room, the guard that covered the belt and pulley on the Dayton Speedaire air compressor was not installed, thereby exposing employees to the hazards associated with moving machine parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 2 instances 3 exposed
Issued
Jul 25, 2017
Abate by
Jul 31, 2017
Penalty
Initial $10,755 · Current $3,764 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:     a.  On or about April 6, 2017, in the coil room , the electrical panel located behind the coiler did not have all opening effectively closed, thereby exposing employees to the hazards associated with electrical shock.    b.  On or about April 6, 2017, in the coil room, the electrical panel located next to the office/ break room did not have all opening effectively closed, thereby exposing employees to the hazards associated with electrical shock.
Recent events (2)
  • — I (S) $3764.25
  • — Z (S) $10755

1910.303 E01 II

Serious Gravity 1 2 instances 3 exposed
Issued
Jul 25, 2017
Abate by
Jul 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(e)(1)(ii): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: Other markings giving voltage, current, wattage, or other ratings as necessary.  a.  On or about April 6, 2017, in the coil room the Square D electrical panels were not marked to indicate voltage, thereby exposing employees to the hazards of electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C02 I A

Serious Gravity 10 2 instances 6 exposed
Issued
Jul 25, 2017
Abate by
Aug 4, 2017
Penalty
Initial $25,097 · Current $8,794 Reduced
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s).    a. On or About April 6, 2017, on the L&J presses serial numbers 52001 and 51966 , the point of operation of the presses were not fully guarded, thereby exposing employees to amputation hazards.     The Meyer Steel Drum, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.217(c)(2)(I)(a), which was contained in OSHA inspection number 1140927, citation number 1, item number 7 and was affirmed as a final order on August 11, 2016, with respect to a workplace located at 2000 S. Kilbourn, Chicago, IL 60623.
Recent events (2)
  • — I (S) $8794
  • — Z (R) $25097

View Meyer Steel Drum, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342233939.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.