2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TOYODA GOSEI MISSOURI CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TOYODA GOSEI MISSOURI CORPORATION in 2200 PLATTIN RD., PERRYVILLE, MO 63775 (NAICS 336399). OSHA activity number 342245941.

Watch Toyoda Gosei Missouri Corporation — free Get an email when a new federal OSHA severe-injury report for Toyoda Gosei Missouri Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2200 PLATTIN RD.
City
PERRYVILLE
State
MO
ZIP
63775
Mailing
2200 PLATTIN RD., PERRYVILLE, MO 63775
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
1700
Ownership type
A

2 citations on file for this inspection.

1910.132 D01 I

Other-than-serious 3 instances 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1)(i): When the employer had assessed the workplace hazard(s) and determined that hazard(s) were present, the employer did not select and/or use the types of personal protective equipment that would protect the affected employee from the hazard:  a. For work in the quality control lab where glacial acetic acid was used for testing parts, the written hazard assessment stated PVC or neoprene glove material was to be used in contradiction of rubber or nitrile glove material stated on the safety data sheet, and which was actually the glove material that has been recently used in the lab.  (Note: neoprene gloves were also available for use.)  b. The written hazard assessment was not specific for body protection to be used during testing with glacial acetic acid.   c. No sanitary wipes or other method for cleaning the face shield were provided.  Written abatement documentation is required for this violation.
Recent events (1)
  • — Z (O) $0

1910.1200 H03 I

Other-than-serious 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area (such as monitoring conducted by the employer and continuous monitoring devices):  For work in the quality control lab where glacial acetic acid was used for testing parts, the written work instruction stated to "confirm that air flow in hood is drawing at a minimum of 100 fpm (paint booth has an anemometer)," however no anemometer was present and there was no apparent alternative method employees could use to determine designated air flow.   Written abatement documentation is required for this violation.