NORTH EAST, PA —
OSHA Inspection: EUREKA ELECTRICAL PRODUCTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of EUREKA ELECTRICAL PRODUCTS, INC. in 79 CLAY STREET, NORTH EAST, PA 16428 (NAICS 331522). OSHA activity number 342269974.
Where did this inspection happen?
- Establishment
- EUREKA ELECTRICAL PRODUCTS, INC.
- Site address
- 79 CLAY STREET
- City
- NORTH EAST
- State
- PA
- ZIP
- 16428
- Mailing
- P.O. BOX 230, NORTH EAST, PA 16428
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331522
- Employees
- 13
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2050.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Eureka Electric Products, Inc. / 79 Clay St, North East, PA: On or about April 19, 2017 and times prior thereto employees were performing servicing and maintenance on equipment including, but not limited to, saws, presses and lathes and other equipment as needed. The employer did not have machine specific lockout tagout procedures.
Recent events (2)
- — I (S) $2050
- — Z (S) $3622
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Eureka Electric Products, Inc. / 79 Clay St, North East, PA: On or about April 19, 2017 and times prior thereto, employees performed servicing and maintenance on equipment including, but not limited to, saws, presses and lathes and other equipment as needed. Periodic inspections of the control of hazardous energy procedures (lockout/tagout) were not performed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) Eureka Electric Products, Inc. / 79 Clay St, North East, PA: On or about April 19, 2017 and times prior thereto, employees were performing servicing and maintenance on equipment including, but not limited to, saws, presses and lathes and other equipment as needed. The employer did not have a Lockout Tagout training program nor documentation of Lockout Tagout training conducted.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $2050.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the Fong Ho Circular Cold Saw labeled as machine #245 did not have guarding to protect the unused portion of the saw blade. b) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the Barker milling machine did not have guarding to protect the blade and belt pulley system. c) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the band sander in the table did not have guarding to protect from moving/rotating parts. d) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the Bliss C-45 labeled as #169 did not have point of operation guarding to protect the employee. e) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the saw labeled as number #109 in the commutator area did not have guarding in place to protect the unused portion of the saw blade.
Recent events (2)
- — I (S) $2050
- — Z (S) $3622
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the Fong Ho Circular Cold Saw labeled as machine #245 the point of operation guarding did not prevent employees from accessing the danger zone. The height and width of the opening is larger than parts being processed. b) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the press labeled as #4 point of operation guarding did not prevent employees from accessing the danger zone. The adjustable barrier guards did not prevent access to the point of operation. The adjustable barrier guards protected the front and sides of the point of operation, but not the top. c) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the press labeled as #13 point of operation guarding did not prevent employees from accessing the danger zone. The adjustable barrier guards did not prevent access to the point of operation. The adjustable barrier guards protected the front and sides of the point of operation, but not the top.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a): a) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the press labeled as #4 did not have guarding in place over the flywheel. b) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the press labeled as #13 did not have guarding in place to protect from the flywheel. c) Eureka Electrical Products, Inc. / 79 Clay St., North East, PA: On or about April 19, 2017 the saw labeled as number #109 in the commutator area, the guard for the upper and lower flywheels was broken in several areas exposing moving parts. Additionally, the guard on the top did not cover the lower section of the flywheel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at EUREKA ELECTRICAL PRODUCTS, INC.
NORTH EAST, PA—2017-03-23 00:00:00
EUREKA ELECTRICAL PRODUCTS, INC.
North East, PA—1982-01-15
EUREKA ELECTRICAL PRODUCTS INC
North East, PA—1981-03-23
EUREKA ELECTRICAL PRODUCTS INC
North East, PA—1981-02-19
EUREKA ELECTRICAL PRODUCTS INC
North East, PA—1973-10-10
EUREKA ELECTRICAL PRODUCTS INC
View EUREKA ELECTRICAL PRODUCTS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331522)
ALBANY, OR—2025-08-25
317741680 - SELMET INC
FLETCHER, NC—2025-03-17
158486 - LINAMAR LIGHT METALS-MR, LLC
WINONA, MN—2024-09-10 00:00:00
108066 - EQUALITY DIE CAST INC
FLETCHER, NC—2024-06-10 00:00:00
156859 - LINAMAR LIGHT METALS-MR, LLC
ALBANY, OR—2024-02-22 00:00:00
317735631 - SELMET INC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342269974.