2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: POWER COMPONENT SYSTEMS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POWER COMPONENT SYSTEMS, INC. in 5455 CARLISLE PIKE BLDG 307, MECHANICSBURG, PA 17050 (NAICS 238910). OSHA activity number 342291101.

Watch Power Component Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Power Component Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5455 CARLISLE PIKE BLDG 307
City
MECHANICSBURG
State
PA
ZIP
17050
Mailing
801 SPANGLER ROAD, CAMP HILL, PA 17011
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
275
Ownership type
A

7 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7243.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:  a) Power Component Systems, Incorporated 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - The employer did not initiate and maintain accident prevention programs to ensure employee safety to include, but not limited to, frequent and regular inspections made by a competent person to ensure the use of appropriate fall protection, the safe use of ladders, and lead paint were identified in the furnace room of building 307, on or about April 27, 2017.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $0
  • — C (S) $7243
  • — Z (S) $7243

1926.62 D01 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7243.00 · Current $7243.00

Hazardous substances 1591

29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 ug/m3) calculated as an 8-hour time-weighted average (TWA):    (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - The employer did not conduct an initial determination of the employees' lead exposure for the employees using a reciprocating saw to cut the lead containing housing while dismantling the furnace, on or about April 27, 2017.    Abatement certification required within 10 days after abatement. The certification shall include statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $7243
  • — C (S) $7243
  • — Z (S) $7243

1926.62 D02 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 1591

29 CFR 1926.62(d)(2)(i): Until the employer performed an employee exposure assessment, as required in 29 CFR 1926.62(d), and documented that the employee(s) performing any of the listed tasks was not exposed above the Permissible Exposure Limit (PEL), the employer did not treat affected employee(s) as if they were exposed above the PEL, and not in excess of ten times the PEL, and did not implement employee protective measures prescribed in 29 CFR 1926.62(d)(2)(v):    (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA Furnace Area - The employer did not perform an exposure assessment or treat the exposure as above the permissible exposure limit and provide and require the use of; respiratory protection, change areas, or biological monitoring, on or about April 27, 2017.    Abatement certification required within 10 days after abatement. The certification shall include statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.501 B01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $10864.00 · Current $0.00 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  (a)  Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA  -The employer did not ensure that employees standing on the cat walk, were protected from falls, with guard rails, safety nets or personal fall protection, thereby exposing employees to a fall hazard of approximately 7 feet 3 inch fall, on or about April 27, 2017.      No abatement certification or documentation is required.
Recent events (3)
  • — F (S) $0
  • — C (S) $10864
  • — Z (S) $10864

1926.502 D16 III

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level:    (a)  Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA  -The employer did not ensure that employees anchored on the right side of the furnace and were working on the left side of the furnace was rigged such that an employee could not free fall more than 6 feet, thereby exposing employees to a fall hazard of approximately 7 feet 3 inch fall, on or about April 27, 2017.        No abatement certification or documentation is required.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1926.850 A

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $7243.00 · Current $7243.00
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations:    (a) 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA  - An engineering survey was not conducted by a competent person prior to employees(s) commencing demolition operations, thereby exposing employee(s) to a possible unplanned structural collapse, on or about April 27, 2017.      No abatement certification or documentation required.
Recent events (3)
  • — F (O) $7243
  • — C (S) $7243
  • — Z (S) $7243

1926.1053 B13

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $5432.00 · Current $5432.00
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step:    (a)  Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA  - Employees were using a Warner 6 foot fiberglass stepladder to access a catwalk around the furnace that was 7 feet 3 inches high, thereby exposing employees to a fall hazard, on or about April 27, 2017.    No abatement certification or documentation required.
Recent events (3)
  • — F (O) $5432
  • — C (S) $5432
  • — Z (S) $5432

View POWER COMPONENT SYSTEMS, INC.'s full OSHA safety record →