MECHANICSBURG, PA —
OSHA Inspection: POWER COMPONENT SYSTEMS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of POWER COMPONENT SYSTEMS, INC. in 5455 CARLISLE PIKE BLDG 307, MECHANICSBURG, PA 17050 (NAICS 238910). OSHA activity number 342291101.
Where did this inspection happen?
- Establishment
- POWER COMPONENT SYSTEMS, INC.
- Site address
- 5455 CARLISLE PIKE BLDG 307
- City
- MECHANICSBURG
- State
- PA
- ZIP
- 17050
- Mailing
- 801 SPANGLER ROAD, CAMP HILL, PA 17011
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238910
- Employees
- 275
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $7243.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: a) Power Component Systems, Incorporated 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - The employer did not initiate and maintain accident prevention programs to ensure employee safety to include, but not limited to, frequent and regular inspections made by a competent person to ensure the use of appropriate fall protection, the safe use of ladders, and lead paint were identified in the furnace room of building 307, on or about April 27, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (S) $0
- — C (S) $7243
- — Z (S) $7243
1926.62 D01 I
- Issued
- Abate by
- Penalty
- Initial $7243.00 · Current $7243.00
1591
General-duty citation text
29 CFR 1926.62(d)(1)(i): Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 ug/m3) calculated as an 8-hour time-weighted average (TWA): (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - The employer did not conduct an initial determination of the employees' lead exposure for the employees using a reciprocating saw to cut the lead containing housing while dismantling the furnace, on or about April 27, 2017. Abatement certification required within 10 days after abatement. The certification shall include statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $7243
- — C (S) $7243
- — Z (S) $7243
1926.62 D02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1926.62(d)(2)(i): Until the employer performed an employee exposure assessment, as required in 29 CFR 1926.62(d), and documented that the employee(s) performing any of the listed tasks was not exposed above the Permissible Exposure Limit (PEL), the employer did not treat affected employee(s) as if they were exposed above the PEL, and not in excess of ten times the PEL, and did not implement employee protective measures prescribed in 29 CFR 1926.62(d)(2)(v): (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA Furnace Area - The employer did not perform an exposure assessment or treat the exposure as above the permissible exposure limit and provide and require the use of; respiratory protection, change areas, or biological monitoring, on or about April 27, 2017. Abatement certification required within 10 days after abatement. The certification shall include statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Penalty
- Initial $10864.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA -The employer did not ensure that employees standing on the cat walk, were protected from falls, with guard rails, safety nets or personal fall protection, thereby exposing employees to a fall hazard of approximately 7 feet 3 inch fall, on or about April 27, 2017. No abatement certification or documentation is required.
Recent events (3)
- — F (S) $0
- — C (S) $10864
- — Z (S) $10864
1926.502 D16 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA -The employer did not ensure that employees anchored on the right side of the furnace and were working on the left side of the furnace was rigged such that an employee could not free fall more than 6 feet, thereby exposing employees to a fall hazard of approximately 7 feet 3 inch fall, on or about April 27, 2017. No abatement certification or documentation is required.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.850 A
- Issued
- Penalty
- Initial $7243.00 · Current $7243.00
General-duty citation text
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations: (a) 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - An engineering survey was not conducted by a competent person prior to employees(s) commencing demolition operations, thereby exposing employee(s) to a possible unplanned structural collapse, on or about April 27, 2017. No abatement certification or documentation required.
Recent events (3)
- — F (O) $7243
- — C (S) $7243
- — Z (S) $7243
1926.1053 B13
- Issued
- Penalty
- Initial $5432.00 · Current $5432.00
General-duty citation text
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: (a) Power Component Systems, Incorporated - 5455 Carlisle Pike Navy Bldg 307 Mechanicsburg PA - Employees were using a Warner 6 foot fiberglass stepladder to access a catwalk around the furnace that was 7 feet 3 inches high, thereby exposing employees to a fall hazard, on or about April 27, 2017. No abatement certification or documentation required.
Recent events (3)
- — F (O) $5432
- — C (S) $5432
- — Z (S) $5432
More inspections at POWER COMPONENT SYSTEMS, INC.
GREENWOOD, DE—2025-05-15
POWER COMPONENT SYSTEMS INC.
SPOTSYLVANIA, VA—2024-11-26
POWER COMPONENT SYSTEMS, INC.
SNOW HILL, MD—2024-04-16 00:00:00
POWER COMPONENT SYSTEMS, INC.
SPOTSYLVANIA, VA—2023-08-15 00:00:00
POWER COMPONENT SYSTEMS, INC.
LORTON, VA—2022-08-18 00:00:00
POWER COMPONENT SYSTEMS INC
View POWER COMPONENT SYSTEMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238910)
SIOUX FALLS, SD—2026-07-10
SOUKUP CONSTRUCTION, INC.
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
BAKERSFIELD, CA—2026-07-10
BENCHMARK PIPELINE INC.
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
AMERICAN CANYON, CA—2026-07-10
ENVIRONCARE INTERNATIONAL
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342291101.