Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOSPITAL OF THE UNIVERSITY OF PENNSYLVANIA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HOSPITAL OF THE UNIVERSITY OF PENNSYLVANIA in 3400 SPRUCE STREET, PHILADELPHIA, PA 19104 (NAICS 622110). OSHA activity number 342301116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hospital of the University of Pennsylvania — free Get an email when a new federal OSHA severe-injury report for Hospital of the University of Pennsylvania is published. One employer, no account, unsubscribe in one click.
Site address
3400 SPRUCE STREET
City
PHILADELPHIA
State
PA
ZIP
19104
Mailing
3624 MARKET ST. SAFETY MANAGEMENT DEPT. 575, PHILADELPHIA, PA 19104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
125
Ownership type
A

3 citations on file for this inspection.

1910.23 B09

Other-than-serious 1 instance 1 exposed
Issued
Jun 2, 2017
Abate by
Jun 14, 2017
Penalty
Initial $8,149 · Current $5,297 Reduced
29 CFR 1910.23(b)(9): Ladders were not inspected before initial use in each work shift, and more frequently as necessary, to identify any visible defects that could cause employee injury;    1) Jobsite: The employer did not ensure that the Louisville ladder used to access upper floors was inspected for visible defects exposing employees to fall hazards.    Condition was noted on or about 3 MAR 2017
Recent events (2)
  • — I (O) $5296.85
  • — Z (S) $8149

1910.23 B10

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 2, 2017
Abate by
Jun 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.23(b)(10):  Ladders with structural or other defects were not immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with �1910.145 and removed from service until repaired in accordance with �1910.22(d), or replaced;  1) Jobsite: The Louisville ladder used to access upper floors was missing its feet preventing the ladder from being set on a firm foundation. The employer did not tag the ladder "Dangerous: Do Not Use" exposing employees to fall hazards.  Condition was observed on or about 3 MAR 2017
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.23 C09

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 2, 2017
Abate by
Jun 14, 2017
Penalty
Initial $8,149 · Current $5,297 Reduced
29 CFR 1910.23(c)(9): Portable ladders used on slippery surfaces were not secured and stabilized;    1) Jobsite: A Louisville ladder used to access upper floors was placed on a smooth concrete surface without its feet. The ladder was not secured and an employee fell approximately 8 feet.    Condition was noted on 3 MAY 2017