Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHERYL HARDWICK DBA PIZZA MAN

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CHERYL HARDWICK DBA PIZZA MAN in 103 S LAFAYETTE ST, NEWTON, IL 62448 (NAICS 722211). OSHA activity number 342302908.

Watch Cheryl Hardwick DBA Pizza MAN — free Get an email when a new federal OSHA severe-injury report for Cheryl Hardwick DBA Pizza MAN is published. One employer, no account, unsubscribe in one click.
Site address
103 S LAFAYETTE ST
City
NEWTON
State
IL
ZIP
62448
Mailing
103 S LAFAYETTE ST, NEWTON, IL 62448
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722211
Employees
9
Ownership type
A

10 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition:  The employer did not ensure that the floor of the kitchen area was kept free of excess water, exposing employees to slips and same-level fall hazards.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.36 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  The employer did not ensure that the back door was able to be opened without special knowledge of the deadbolt and wooden bar used to secure the exit from the inside of the building.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.37 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  The employer did not ensure that the doorway in the back storage room was marked with an "Exit" sign.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.38 B

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review, or communicated orally in an establishment with 10 or fewer employees:  The employer did not ensure that an emergency action plan was orally communicated to employees, who are exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 A03 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $2173.00

Hazardous substances 8400

29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:    The employer did not ensure that the walls in the back storage room were free from the accumulation of bird feces, exposing employees to biological hazards.
Recent events (3)
  • — A (S) $2173
  • — I (S) $1521
  • — Z (S) $2173

1910.141 A05

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8400

29 CFR 1910.141(a)(5): Enclosed workplaces were not so constructed, equipped, and maintained as to prevent the entrance or harborage of rodents, insects, or other vermin:  The employer did not ensure that the building was maintained as to prevent the harborage of birds in the ceiling of the back storage room of the facility.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  The employer did not ensure that the Class ABC and Class K fire extinguishers stored in the kitchen area received annual inspections in 2015, 2016, and 2017 year-to-date.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  The employer did not ensure that electrical equipment was not used or as intended, where: a) The circuit breakers for interior and exterior lighting were being used as switches and were not rated as such, and b) A box fan was being used while resting in a water puddle and was not rated for use in a wet environment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  In the back storage room, an extension cord was being used to power a stationary dough roller in the middle of the room.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  The employer did not ensure that the circuit breaker panel box contained a label indicating the purpose of each circuit breaker device each location.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342302908.