Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: VULCAN MANUFACTURING COMPANY, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VULCAN MANUFACTURING COMPANY, INC. in 4125 UNIVERSITY BLVD COURT, JACKSONVILLE, FL 32217 (NAICS 333516). OSHA activity number 342535184.

Watch Vulcan Manufacturing Company, INC. — free Get an email when a new federal OSHA severe-injury report for Vulcan Manufacturing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4125 UNIVERSITY BLVD COURT
City
JACKSONVILLE
State
FL
ZIP
32217
Mailing
PO BOX 5825, JACKSONVILLE, FL 32247
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333516
Employees
12
Ownership type
A

4 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2463.00 · Current $1478.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  a. On August 9, 2017, the employer did not provide adequate forklift training such as site specific training, video, lecture, testing and written certification to forklift operators.
Recent events (2)
  • — I (S) $1477.8
  • — Z (S) $2463

1910.217 D05

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $3078.00 · Current $1847.00 Reduced
29 CFR 1910.217(d)(5): Unitized tooling. When unitized tooling was used, the opening between the top of the punch holder and the face of the slide, or striking pad, was not safeguarded in accordance with the requirements of paragraph (c) of this section:  a. On August 9, 2017, the Chicago K & D mechanical full revolution press brake used with a unitized tool as a power press did not have a guard to cover the opening above the tool and below the ram, exposing employees to an amputation hazard.
Recent events (2)
  • — I (S) $1846.8
  • — Z (S) $3078

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2463.00 · Current $1478.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  a. On August 9, 2017, in both shops, there were oxygen cylinders stored near methane and acetylene cylinders, exposing employees to a fire hazard.
Recent events (2)
  • — I (S) $1477.8
  • — Z (S) $2463

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): Employers did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met:  a. On August 9, 2017, the employer did not have a hazard communication program to inform employees about the hazards of the chemicals used in the facility such as acids, paints, oils, and gases.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View VULCAN MANUFACTURING COMPANY, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342535184.