1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ENGINEERED WIRE PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENGINEERED WIRE PRODUCTS, INC. in 3121 WEST MARKET STREET, WARREN, OH 44485 (NAICS 332618). OSHA activity number 342604543.

Watch Engineered Wire Products, INC. — free Get an email when a new federal OSHA severe-injury report for Engineered Wire Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3121 WEST MARKET STREET
City
WARREN
State
OH
ZIP
44485
Mailing
3121 WEST MARKET STREET, WARREN, OH 44485
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
190
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6926.00 · Current $9696.00
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about 8/31/2017, and at times before, the employer failed to ensure that employees manually removing rebar mesh from the MG215 (Typ 32.14/16D Nr GS1.4174.5622 & Typ ZG 32 QKVI/1 Nr GS1.4516.5622) utilized lockout procedures. At times when the MG215 timed out due to an error in the programming, or the hooks missed when picking up the rebar mesh to advance it, employees were climbing onto the Typ ZG 32 QKVI/1 Nr GS1.4516.5622, to gain access to the wire rebar mesh to remove the mesh by hand without following lockout procedures as required by 29 CFR 1910.147(d)(1)-(6) as follows:    1) Preparation for shutdown;  2) Machine or equipment shutdown;  3) Machine or equipment isolation;  4) Lockout device application;  5) Relieve/disconnect/render safe stored energy, and;  6) Verification of isolation.
Recent events (2)
  • — I (S) $9696
  • — Z (S) $6926

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6926.00 · Current $0.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about 8/31/2017, and at times before, the employer failed to ensure that employees manually removing rebar mesh from the MG215 (Typ 32.14/16D Nr GS1.4174.5622 & Typ ZG 32 QKVI/1 Nr GS1.4516.5622) were protected with machine guarding methods. At times when the MG215 timed out due to an error in the programming, and/or the hooks missed when picking up the rebar mesh to advance it, employees were climbing onto the Typ ZG 32 QKVI/1 Nr GS1.4516.5622, to gain access to the wire rebar mesh to remove the mesh by hand without being protected with machine guarding methods.