OSHA Inspection: HORTICOPIA LANDSCAPING LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of HORTICOPIA LANDSCAPING LLC in 684 FREELING DRIVE, SIESTA KEY, FL 34242 (NAICS 561730). OSHA activity number 342660396.

Watch Horticopia Landscaping LLC — free Get an email when a new federal OSHA severe-injury report for Horticopia Landscaping LLC is published. One employer, no account, unsubscribe in one click.
Site address
684 FREELING DRIVE
City
SIESTA KEY
State
FL
ZIP
34242
Mailing
2310 WALDEMERE STREET, SARASOTA, FL 34239
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.67 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $1386.00 Reduced
29 CFR 1910.67(c)(2)(v): A body belt was not worn and lanyard was not attached to the boom or basket when working from an aerial lift:     (a) An employee involved in tree trimming operations, while standing in the cage/platform of a Platform Basket 18.90 Pro tracked aerial lift, was not wearing a body belt with lanyard attached to the platform, on or or about September 24, 2017.
Recent events (2)
  • — I (S) $1386
  • — Z (S) $2772

1910.333 C03 III A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12934.00 · Current $11641.00 Reduced
29 CFR 1910.333(c)(3)(iii)(A): Vehicles or mechanical equipment capable of having parts of their structures elevated near energized overhead lines were not operated so that a clearance of 10 feet (305 cm) was maintained:     (a) An employee involved in tree trimming operations, while standing in the cage/paltform of a Platform Basket 18.90 tracked aerila lift, moved the aerila lift such that the aerial lift contacted a 7.62 kV (7620-volt) overhead power line on the north side of a residential property located at 684 Freeling Drive, Siesta Key, FL, on or about September 24, 2017.
Recent events (2)
  • — I (S) $11640.6
  • — Z (S) $12934