Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PREMIER WORKFORCE SOLUTIONS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PREMIER WORKFORCE SOLUTIONS, LLC in 432 EAST WASHINGTON STREET, WEST BEND, WI 53095 (NAICS 561311). OSHA activity number 342695285.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Premier Workforce Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Premier Workforce Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
432 EAST WASHINGTON STREET
City
WEST BEND
State
WI
ZIP
53095
Mailing
1652 NORTH MAIN STREET, RACINE, WI 53402
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561311
Employees
7
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 27, 2017
Abate by
Jan 3, 2018
Penalty
Initial $8,873 · Current $3,000 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    (a) The employer did not develop, document and utilize specific energy control procedures (lockout/tag out program), conduct periodic audits and did not provide adequate training on the energy control procedure to ensure that all required elements of the procedure were understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees performing servicing such as but not limited to belt and pulley changes on HVAC and changing ceiling lights ballast.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $8873

1910.332 B02

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 27, 2017
Abate by
Jan 3, 2018
Penalty
Initial $8,873 · Current $3,000 Reduced
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety.    (a) Employees who were not qualified persons and covered by 1910.332 (a) were not trained electrical safety practices.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342695285.