Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: NUTEC TOOLING SYSTEMS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NUTEC TOOLING SYSTEMS, INC. in 18114 RESEARCH DRIVE, MEADVILLE, PA 16335 (NAICS 332999). OSHA activity number 342700499.

Watch Nutec Tooling Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Nutec Tooling Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
18114 RESEARCH DRIVE
City
MEADVILLE
State
PA
ZIP
16335
Mailing
18114 RESEARCH DRIVE, MEADVILLE, PA 16335
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
58
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 8 instances 3 exposed
Issued
Abate by
Penalty
Initial $6467.00 · Current $4527.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  A.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts.  The wheels of the belt sander and the unused portion of the sanding belt were not guarded to prevent hazards of skin abrasion, in-running nip points, and rotating end shafts.  B.)    Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Kalamazoo Industries one-inch bench top belt sander for operations including, but not limited to, deburring parts.  The wheels of the belt sander and the unused portion of the sanding belt were not guarded to prevent hazards of skin abrasion, and in-running nip points.  C.)    Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock.  The band saw was not equipped with an adjustable guard to protect the unused portion of the band saw blade and the blade saw guide wheels.    D.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock.  The band saw door was not complete in that it did not completely protect the band saw blade on the return side.    E.)    Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #182) for operations including, but not limited to, cutting metal stock.  The bottom wheel of the band saw and the band saw blade were not guarded.    F.)    Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock.  The band saw was not equipped with an adjustable guard to protect the unused portion of the band saw blade and the blade saw guide wheels.    G.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock.  The band saw door was not complete in that it did not completely protect the band saw blade on the return side.    H.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the Roll-In Band Saw (Asset #215) for operations including, but not limited to, cutting metal stock.  The bottom wheel of the band saw and the band saw blade were not guarded.
Recent events (2)
  • — I (S) $4526.9
  • — Z (S) $6467

1910.219 D01

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  A.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts.  The guard for the belt sander's power transmission system belt and pulley system was ineffective in that the front of the guard was open.  The belt and pulley system was at least 42-inches above the floor.   B.)   Nutec Tooling Systems, Inc., 18114 Research Drive, Meadville, PA  16335, band saw area, on or about October 13, 2017 and times prior thereto:  Employees utilize the one-inch bench top belt sander for operations including, but not limited to, deburring parts.  The guard for the belt sander's power transmission system belt and pulley system was ineffective in that the back of the guard was open.  The belt and pulley system was at least 42-inches above the floor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  A.)  Nutec Tooling Systems, Inc., assembly A, on or about October 13, 2017 and times prior thereto:  An Amerex carbon dioxide fire extinguisher (M/N: 331, S/N: X-270150) was on the floor and was not mounted to a wall surface.  B.)  Nutec Tooling Systems, Inc., shipping and receiving area, on or about October 13, 2017 and times prior thereto:  A Kidde multi-purpose dry chemical fire extinguisher (M/N: PRO 10 TCM-2, S/N:  KL-137498) was located within 6-inches of items stored on the counter in shipping and receiving.  The location of the fire extinguisher did not make the fire extinguisher readily accessible.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View NUTEC TOOLING SYSTEMS, INC.'s full OSHA safety record →