Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CST INDUSTRIES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of CST INDUSTRIES, INC. in 2101 S 21ST ST., PARSONS, KS 67357 (NAICS 332311). OSHA activity number 342789864.

Watch CST Industries, INC. — free Get an email when a new federal OSHA severe-injury report for CST Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2101 S 21ST ST.
City
PARSONS
State
KS
ZIP
67357
Mailing
P.O. BOX 996, PARSONS, KS 67357
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
650
Ownership type
A

5 citations on file for this inspection.

1910.134 I01 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7391.00 · Current $0.00 Reduced
29 CFR 1910.134(i)(1)(ii): The employer did not ensure that compressed air used for respiration accords with the following specifications: Compressed breathing air shall meet at least the requirements for Grade D breathing air as described in ANSI/ Compressed Gas Association Commodity Specification for Air, G-7.1-198.  (a) Employees engaged in blasting or painting activities mandatorily to utilize supplied air hood were exposed to health hazards in that level of oxygen content was not monitored.  (b) Employees engaged in blasting or painting activities mandatorily to utilize supplied air hood were exposed to health hazards in that level of hydrocarbon content was not monitored.  (c) Employees engaged in blasting or painting activities mandatorily to utilize supplied air hood were exposed to health hazards in that level of carbon dioxide was not monitored.
Recent events (3)
  • — F (S) $0
  • — C (S) $7391
  • — Z (S) $7391

1910.253 B04 III

Deleted Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $0.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  Employees engaged in welding activities located at east wall of weld shop were exposed to fire hazards in that oxygen cylinders were stored next to flammable cylinders containing acetylene.  The fire wall which separated the cylinders included a void which resulted in the fire wall not being at least 5 feet high with a fire rating of at least one-half hour.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.1200 E01 II

Deleted Serious Gravity 1 1 instance 170 exposed
Issued
Abate by
Penalty
Initial $5543.00 · Current $0.00 Reduced
29 CFR 1910.1200(e)(1)(ii): Employer's written Hazard Communication Program did not address methods the employer would use to inform employees of the hazards of non-routine tasks:  Employees engaged in production activities using hazardous chemicals, including but not limit to flammable paint KPW0614, compressed oxygen and dissolved acetylene, and welding stainless steel, were exposed the health hazards in that information regarding non-routine task was not established and included in the hazard communication program.
Recent events (3)
  • — F (S) $0
  • — C (S) $5543
  • — Z (S) $5543

1910.134 D01 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $9239.00 · Current $0.00 Reduced

Hazardous substances 06890691

29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazards in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:   Employees engaged in production activities requiring welding on stainless steel were exposed to hexavalent chromium hazards in that an evaluation and estimation of respiratory hazards associated with this activity had not been conducted.
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.1026 D02 III

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 06890691

29 CFR 1910.1026(d)(2)(iii): If monitoring reveals employee exposures to be at or above the action level, the employer shall perform periodic monitoring at least every six months.  On or about December 11, 2017, an employee welding stainless steel in the weld shop and was exposed to hexavalent chromium at an eight-hour time-weighted average level of 12.8 micrograms per cubic meter, approximately 5.12 times over the action level of 2.5 microgram per cubic meter, derived from one sample collected over 480 minutes period.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View CST INDUSTRIES, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342789864.