MACOMB, IL —
OSHA Inspection: ROBERT WEAVER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROBERT WEAVER in 4007 W. JACKSON STREET, MACOMB, IL 61455 (NAICS 238160). OSHA activity number 342832649.
Where did this inspection happen?
- Establishment
- ROBERT WEAVER
- Site address
- 4007 W. JACKSON STREET
- City
- MACOMB
- State
- IL
- ZIP
- 61455
- Mailing
- 1426 N. COUNTY ROAD 3000, TENNESSEE, IL 62374
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain an accident prevention program as may be necessary to comply with this part. On or about December 12, 2017, employees were exposed to fall hazards and the employer did not have an effective safety and health program with specific work rules, competent person oversight, and employee training to govern employees' activities.
Recent events (3)
- — F (S) $0
- — C (S) $2173
- — Z (S) $2173
1926.451 B01 I
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. On or about December 12, 2017, an employee was exposed to fall hazards from a frame scaffold and there was approximately 5-inches of space between the 12-inch plank and the outermost uprights.
Recent events (3)
- — F (S) $0
- — C (S) $2173
- — Z (S) $2173
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration and such activities were not performed by only experienced and trained employees: On or about December 12, 2017, employees used a frame scaffold that was not inspected by a competent person and employees were exposed to fall hazards when they used the scaffold to: a) access the roof using the ladder on the scaffold; and b) transferred sheet metal between the gravel driveway and roof.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. On or about December 12, 2017, employees were exposed to falls greater than 16-feet when installing a metal roof and the employer did not provide a suitable fall protection system.
Recent events (3)
- — F (S) $0
- — C (S) $2716
- — Z (S) $2716
1926.1051 A
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): A stairway or ladder was not provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided. On or about December 12, 2017, employees were exposed to injuries and the employer provided the employees a frame scaffold to access the roof with a break in elevation greater than 19-inches between the roof and scaffold plank.
Recent events (3)
- — F (S) $0
- — C (S) $2716
- — Z (S) $2716
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in IL
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
GRANITE CITY, IL—2026-07-13
UNITED STATES STEEL CORPORATION
DECATUR, IL—2026-07-10
TILLAMOOK ILLINOIS, LLC
NEW LENOX, IL—2026-07-10
A.D GENERAL CONSTRUCTION LLC
LOCKPORT, IL—2026-07-09
ROBERTO GOMEZ DBA ROBERTO GOMEZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342832649.