WHITEWATER, CO —
OSHA Inspection: ROBERTS PLUMBING & HEATING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROBERTS PLUMBING & HEATING in 1490 PURDY MESA, WHITEWATER, CO 81527 (NAICS 238220). OSHA activity number 342878949.
Where did this inspection happen?
- Establishment
- ROBERTS PLUMBING & HEATING
- Site address
- 1490 PURDY MESA
- City
- WHITEWATER
- State
- CO
- ZIP
- 81527
- Mailing
- 3196 MESA AVE, GRAND JUNCTION, CO 81504
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.503 A02
- Issued
- Abate by
- Penalty
- Initial $3696.00 · Current $3696.00
General-duty citation text
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a) Roberts Plumbing and Heating Inc. at 1499 Purdy Mesa, Whitewater, CO 81527: On and before January 8, 2018, the employer did not ensure that employees were trained by a competent person about the fall hazards of this site. An employee accessed a steep metal roof without the use of adequate fall protection and training. This condition exposed employees to fall hazards. Abatement note: 29 CFR 1926.503(a)(2) is annotated as follows: The employer shall assure that each employee has been trained, as necessary, by a competent person qualified in the following areas: The nature of fall hazards in the work area; The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; The use and operation of guardrail systems, personal fall arrest systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used; The role of each employee in the safety monitoring system when this system is used; The limitations on the use of mechanical equipment during the performance of roofing work on low-sloped roofs; The correct procedures for the handling and storage of equipment and materials and the erection of overhead protection; The role of employees in fall protection plans; and The standards contained in this subpart.
Recent events (1)
- — Z (S) $3696
1926.1060 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1060(a)(1): The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards: a) Roberts Plumbing and Heating Inc. at 1499 Purdy Mesa, Whitewater, CO 81527: On and before January 8, 2018, the employer did not ensure that employees were trained by a competent person about ladder safety. An employee used a ladder to access a steep metal roof. The employee was not adequately trained on ladder safety. This condition exposed employees to fall hazards. Abatement note: 29 CFR 1926.1060(a)(1) is annotated as follows: The employer shall assure that each employee has been trained, as necessary, by a competent person qualified in the following areas: The nature of fall hazards in the work area; The correct procedures for erecting, maintaining, disassembling, and inspecting the fall protection systems to be used; The proper construction, use, placement, and care in handling of all stairways and ladders; and The standards contained in this subpart.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238220)
LOS ANGELES, CA—2026-07-10
PRIME SC MECHANICAL INC.
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
PONCE, PR—2026-07-10
WILLIAM ECHEVARR�A ANDINO
MODESTO, CA—2026-07-09
R.L. FULLER, INC.
SAN JOSE, CA—2026-07-09
ROOTER HERO
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342878949.