1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: DOE RUN RESOURCES CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DOE RUN RESOURCES CORPORATION in 18594 HWY KK, BOSS, MO 65440 (NAICS 331492). OSHA activity number 343089132.

Watch DOE RUN Resources Corporation — free Get an email when a new federal OSHA severe-injury report for DOE RUN Resources Corporation is published. One employer, no account, unsubscribe in one click.
Site address
18594 HWY KK
City
BOSS
State
MO
ZIP
65440
Mailing
18594 HWY KK, BOSS, MO 65440
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331492
Employees
300
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6282.00 · Current $6282.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  A specific lockout/tagout procedure was not developed and documented for blast furnace pump #3019, which included electrical and hot water/pressure energy sources.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $6282
  • — Z (S) $6282

1910.147 C06 I C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6282.00 · Current $6282.00
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:  An annual lockout/tagout inspection was not conducted on each authorized employee, such as maintenance men who perform lockout/tagout work on equipment.  Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $6282
  • — Z (S) $6282

1910.147 D03

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $6282.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  The flow valve to pump #3019 in the blast furnace building was not completely closed before lockout work was performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6282

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  The flow valve to pump #3019 in the blast furnace building was not locked out before lockout work was performed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D05 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $6282.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:  The flow valve to pump #3019 in the blast furnace building was not completely closed before lockout work was performed, and the pressure relief valve was not tested to release line water pressure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6282

1910.147 D06

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  The flow valve to pump #3019 in the blast furnace building was not completely closed before lockout work was performed, and energy isolation, that is, water pressure, was not tested, such as by checking the pressure relief valve.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View DOE RUN RESOURCES CORPORATION's full OSHA safety record →