2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: FOREST SERVICE WENATCHEE FORESTRY SCIENCE LAB

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of FOREST SERVICE WENATCHEE FORESTRY SCIENCE LAB in 1133 N WESTERN AVE., WENATCHEE, WA 98801 (NAICS 541712). OSHA activity number 343152930.

Watch Forest Service Wenatchee Forestry Science LAB — free Get an email when a new federal OSHA severe-injury report for Forest Service Wenatchee Forestry Science LAB is published. One employer, no account, unsubscribe in one click.
Site address
1133 N WESTERN AVE.
City
WENATCHEE
State
WA
ZIP
98801
Mailing
1133 N WESTERN AVE., WENATCHEE, WA 98801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541712
Employees
28
Ownership type
D

7 citations on file for this inspection.

1910.157 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  A)    In the greenhouse, one of the fire extinguishers was not properly mounted to provide access and prevent damage.
Recent events (1)
  • — Z (S) $0

1910.212 B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  A)     The drill press in the maintenance shop was not secured to the floor to ensure that it would not move, or tip over while operating.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  A)     In the maintenance shop, the tongue guard on a Delta bench grinder was 5/8 of an inch from the surface of the wheel.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  A)     In the greenhouse, a standard electrical fixture box was used as the housing for electrical outlets on a pendant cord outlet.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  A)     An electric fixture box mounted on the wall of the greenhouse had open holes that were not being used.
Recent events (1)
  • — Z (S) $0

1910.305 F

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(f): All conductors used for general wiring were not insulated:  A)     In the green there was a power strip where part of the cord had decayed to the point that the wiring was exposed.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  A)     In the greenhouse there were pendant cords that were hung from the ceiling without any kind of strain relief attached to the cord.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343152930.