1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: REYNOLDS MANUFACTURING COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of REYNOLDS MANUFACTURING COMPANY in 621 RAILROAD AVENUE, AVONMORE, PA 15618 (NAICS 332313). OSHA activity number 343202768.

Watch Reynolds Manufacturing Company — free Get an email when a new federal OSHA severe-injury report for Reynolds Manufacturing Company is published. One employer, no account, unsubscribe in one click.
Site address
621 RAILROAD AVENUE
City
AVONMORE
State
PA
ZIP
15618
Mailing
621 RAILROAD AVENUE, AVONMORE, PA 15618
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
9
Ownership type
A

11 citations on file for this inspection.

1910.94 A05 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2217.00 · Current $1330.00 Reduced
29 CFR 1910.94(a)(5)(iv):  For employees who use respirators required by this section, the employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134:    a)  Sandblasting Area, on or about June 4, 2018 - The employer did not implement a respiratory protection program for employees who use a blasting hood during sandblasting operations.
Recent events (2)
  • — I (S) $1330
  • — Z (S) $2217

1910.134 C

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:  a)  In the Facility, on or about June 4, 2018 - The employer did not implement a respiratory protection program for employees who use a blasting hood during sandblasting operations and for employees who use a full face respirator during spray painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   a)  In the Facility, on or about June 4, 2018 - The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee is required to use a respirator in the workplace.  Employees use a blasting hood during sandblasting operations and a full face respirator during spray painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):   a)  In the Facility, on or about June 4, 2018 - The employer did not provide a fit test to employees who are required to use a tight fitting respirator in the workplace.  Employees use a full face respirator during spray painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  a)  Sandblasting Area, on or about June 4, 2018 - The blasting hood was not stored to protect it from contamination as it was lying in a pile of blasting material in the sandblasting area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a)  In the Facility, on or about June 4, 2018 - The employer did not provide respirator training to employees who are required to use a respirator in the workplace.  Employees use a blasting hood during sandblasting operations and a full face respirator during spray painting operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.94 A04 I

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $1663.00 · Current $1000.00 Reduced
29 CFR 1910.94(a)(4)(i): The construction, installation, inspection, and maintenance of exhaust systems shall conform to the principles and requirements set forth in American National Standard Fundamentals Governing the Design and Operation of Local Exhaust Systems, Z9.2-1960, and ANSI Z33.1-1961:    a)  Sandblasting Area, on or about June 4, 2018 - The maintenance of the exhaust system in the sandblasting unit did not conform to the principles and requirements set forth in American National Standard Fundamentals Governing the Design and Operation of Local Exhaust Systems, Z9.2-1960 in that the fan element of the exhaust system was inoperable.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1663

1910.244 B

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.244(b): Abrasive blast cleaning nozzle(s) were not equipped with an operating valve which had to be held open manually and a support shall be provided on which the nozzle may be mounted when it is not in use:   a)  Sandblasting Area, on or about June 4, 2018 - The abrasive blast cleaning nozzle was not equipped with an operating valve which had to be held open.  The operating valve was located on the pressure pot.  In addition, a support was not provided to mount the nozzle when not in use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.94 A06

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.94(a)(6): The air for abrasive-blasting respirators was not free of harmful quantities of dusts, mists, or noxious gases, and did not meet the requirements for supplied-air quality and use set forth in 29 CFR 1910.134(i):   a)  Sandblasting Area, on or about June 4, 2018 - The in-line filter used from the air compressor did not meet the requirements of 29 CFR 1910.134(i) in that it did not have a tag containing the most recent change date and the signature of the person authorized by the employer to perform the change.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I05 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:   a)  Sandblasting Area, on or about June 4, 2018 - The in-line filter used from the air compressor did not have a tag containing the most recent change date and the signature of the person authorized by the employer to perform the change.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.94 A07

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.94(a)(7): Dust was permitted to accumulate on the floor or on ledges outside of an abrasive-blasting enclosure, and dust spills were not cleaned up promptly. Aisles and walkways were not kept clear of steel shot or similar abrasive which created a slipping hazard:  a)  Sandblasting Area, on or about June 4, 2018 - Accumulations of dust were not cleaned up promptly in the sandblasting unit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View REYNOLDS MANUFACTURING COMPANY's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343202768.