Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: AMERICAN EAGLE GROUP LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AMERICAN EAGLE GROUP LLC in 604 ROOSEVELT BLVD, PARAMUS, NJ 07652 (NAICS 238130). OSHA activity number 343413993.

Watch American Eagle Group LLC — free Get an email when a new federal OSHA severe-injury report for American Eagle Group LLC is published. One employer, no account, unsubscribe in one click.
Site address
604 ROOSEVELT BLVD
City
PARAMUS
State
NJ
ZIP
07652
Mailing
410 N 6TH STREET-1ST FLOOR, NEWARK, NJ 07107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2772.00 · Current $0.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a- Framed platform: An employee engaged in framing activities was exposed to overhead impact hazards as head protection was not utilized. Condition noted on or about 08/25/2018
Recent events (3)
  • — C (S) $2772
  • — F (S) $0
  • — Z (S) $2772

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2772.00 · Current $2772.00
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:    a- Framed platform: An employee engaged in framing activities was exposed to eye injury hazards while using a pneumatic nail coiler. Condition noted on or about 08/24/2018
Recent events (3)
  • — C (S) $2772
  • — F (S) $2772
  • — Z (S) $2772

1926.416 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3880.00 · Current $0.00 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a- Framed platform: An employee was engaged in framing activities and exposed to electrocution hazards from an energized secondary power line which had not been de-energized prior to use. Condition noted on or about 08/25/2018
Recent events (3)
  • — C (S) $3880
  • — F (S) $0
  • — Z (S) $3880

1926.501 B13

Serious Gravity 10 3 instances 3 exposed
Issued
Penalty
Initial $3880.00 · Current $3880.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system :  a- Framed platform:  Employees engaged in framing activities were exposed to fall hazards of approximately 13ft to the concrete below as a means of fall protection was not utilized. Condition noted on or about 08/24/2018  b-Framed Edge: An employee on 08/25/2018 was observed engaged in framing activities and exposed to fall hazards of approximately 21ft to the concrete below as a personal fall arrest harness was worn but not secured via a lanyard. Condition noted on or about 08/25/2018.  c-Framed Peak: An employee on 08/25/2018 was observed engaged in framing activities and exposed to fall hazards of approximately 23ft to the concrete below as a personal fall arrest harness was worn but not secured via a lanyard. Condition noted on or about 08/25/2018.
Recent events (3)
  • — C (S) $3880
  • — F (S) $3880
  • — Z (S) $3880

1926.1053 B01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3880.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a- Framed platform: Employees engaged in framing activities were exposed to fall hazard of approximately 13ft to the concrete below as the ladder side rails did not extend 3ft above the upper landing surface.Condition noted on or about 08/25/2018
Recent events (3)
  • — C (S) $3880
  • — F (S) $0
  • — Z (S) $3880

1926.1053 B13

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3326.00 · Current $0.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a- Framed platform: An employee was engaged in framing activities and exposed to fall hazards of approximately 8ft while breeching the top step of an A-Frame Ladder. Condition noted on or about 08/25/2018
Recent events (3)
  • — C (S) $3326
  • — F (S) $0
  • — Z (S) $3326

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343413993.