Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECAST WALL SYSTEMS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRECAST WALL SYSTEMS, INC. in 1199 W. LANTANA ROAD, LAKE WORTH, FL 33462 (NAICS 238120). OSHA activity number 343440038.

Watch Precast Wall Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Precast Wall Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1199 W. LANTANA ROAD
City
LAKE WORTH
State
FL
ZIP
33462
Mailing
1888 NW 22ND COURT, POMPANO BEACH, FL 33069
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.1408 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $9282.00 · Current $6498.00 Reduced
29 CFR 1926.1408(b)(1): The employer did not conduct a planning meeting with the operator and the other workers who will be in the area of the equipment or load to review the location of the  power line(s), and the steps that will be implemented to prevent encroachment/electrocution:    On or about September 4, 2018, on the west side of a worksite located at 1199 W. Lantana Road in Lake Worth, Florida, employees were exposed to electrocution hazards when permitted to performing concrete wall panel installation using a wheel mounted crane located within 7 feet or less of overhead power lines energized with 7,620 volts prior to conducting a meeting to discuss the location of the power lines and/or steps to be followed to prevent encroachment/electrocution.
Recent events (2)
  • — I (S) $6498
  • — Z (S) $9282

1926.1410 D01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1410(d)(1): The employer did not hold a planning meeting with the utility owner/operator (or registered professional engineer who is a qualified person with respect to electrical power transmission and distribution) to ensure that a power line equipped with a device that automatically reenergizes the circuit in the event of a power line contact, before the work begins, the automatic reclosing feature of the circuit interrupting device must be made inoperative if the design of the device permits:    On or about September 4, 2018, on the west side of a worksite located at 1199 W. Lantana Road in Lake Worth, Florida, employees were exposed to electrocution hazards when permitted to performing concrete wall panel installation using a wheel mounted crane located within 7 feet or less of overhead power lines energized with 7,620 volts prior to holding a planning meeting with the utility owner/operator to ensure that a power line equipped with a device that automatically reenergizes the circuit in the event of a power line contact was made inoperative.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1408 G01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6630.00 · Current $4642.00 Reduced
29 CFR 1926.1408(g)(1)(i): The crane operator and crew members assigned to work with the equipment were not provided trained in the procedures to be followed in the event of electrical contact with a power line:    On or about September 4, 2018, on the west side of a worksite located at 1199 W. Lantana Road in Lake Worth, Florida, employees were exposed to electrocution hazards when permitted to performing concrete wall panel installation using a wheel mounted crane located within 7 feet or less of overhead power lines energized with 7,620 volts prior to being provided with training to ensure they understood the procedures to be followed in the event of contact with overhead power lines.
Recent events (2)
  • — I (S) $4642
  • — Z (S) $6630

1926.1430 B

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1430(b): The employer did not train employees in the signal qualifications:    On or about September 4, 2018, on the west side of a worksite located at 1199 W. Lantana Road in Lake Worth, Florida, employees were exposed to struck-by and/or caught between hazards when signaling a crane during concrete wall panel installation prior to being provided with training for crane signaling qualifications.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1408 A01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1408(a)(1): The Employer failed to identify the work zone by either demarcating the boundaries or defining the work zone 360 degrees around the equipment:    On or about September 4, 2018, on the west side of a worksite located at 1199 W. Lantana Road in Lake Worth, Florida, employees were exposed to electrocution hazards when performing concrete wall panel installation using a wheel mounted crane located within 7 feet or less of overhead power lines energized with 7,620 volts where the employer failed to identify the work zone to prevent contact with the power lines.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343440038.