MONTGOMERY, AL —
OSHA Inspection: PRECISION METAL WORKS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRECISION METAL WORKS, INC. in 1080 KERSHAW STREET, MONTGOMERY, AL 36108 (NAICS 332999). OSHA activity number 343560660.
Where did this inspection happen?
- Establishment
- PRECISION METAL WORKS, INC.
- Site address
- 1080 KERSHAW STREET
- City
- MONTGOMERY
- State
- AL
- ZIP
- 36108
- Mailing
- 1080 KERSHAW STREET, MONTGOMERY, AL 36108
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 55
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 P01
- Issued
- Penalty
- Initial $4398.00 · Current $4398.00
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s): (a) Saw area: On or about June 14, 2018 and at times prior thereto the employer did not take out of service a defective Nissan forklift model: MCPLO1A18LV; Type: LP; rated capacity of 3,000lbs with missing fork pin on the left side of the fork mast exposing employees to struck by hazards from the fork.
Recent events (1)
- — Z (S) $4398
1910.305 J02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: a) Receptacle installed near break room sink at powder paint building: On or about October 23, 2018, a 125-volt, single-phase, 15 amp or 20 amp receptacle was installed within 6 feet of a break room sink that did not have a ground-fault circuit-interrupter (GFCI) protection for employees who are potentially exposed to electric shock and burn hazards while using the sink during tasks such as, but not limited to, washing dishes and utensils.
Recent events (1)
- — Z (O) $0
More inspections at PRECISION METAL WORKS, INC.
MONTGOMERY, AL—2013-04-09 00:00:00
PRECISION METAL WORKS, INC.
MONTGOMERY, AL—2013-03-07 00:00:00
PRECISION METAL WORKS, INC.
CHANTILLY, VA—2011-02-16 00:00:00
PRECISION METAL WORKS INC
ROSWELL, GA—2005-01-27 00:00:00
PRECISION METAL WORKS, INC.
View PRECISION METAL WORKS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in AL
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
LOXLEY, AL—2026-07-16
CARLOS CHE
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
BIRMINGHAM, AL—2026-07-14
SCHOLAR CRAFT PRODUCTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343560660.