Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BILL SCHOENECKER CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BILL SCHOENECKER CONSTRUCTION, LLC in 822 SKY PARK AVE, HARTFORD, WI 53027 (NAICS 236115). OSHA activity number 343605523.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bill Schoenecker Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Bill Schoenecker Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
822 SKY PARK AVE
City
HARTFORD
State
WI
ZIP
53027
Mailing
N5116 COUNTY RD U, HARTFORD, WI 53027
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
1
Ownership type
A

3 citations on file for this inspection.

1926.451 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2019
Abate by
Apr 17, 2019
Penalty
Initial $2,842 · Current $1,989 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  (a) The employer did not ensure that employees were using fall protection when conducting work from an elevated platform during framing carpentry work on a residential building.
Recent events (2)
  • — I (S) $1989.4
  • — Z (S) $2842

1926.451 A06

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2019
Abate by
Apr 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.  (a)  The scaffold work platform used to elevated employees on the New Holland Telehandler rough terrain forklift was not designed by a qualified person.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 5, 2019
Abate by
Apr 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied:  (a)  The employer did not ensure that an elevated platform used to support persons, material and equipment was attached to the forks of the New Holland Telehandler rough-terrain forklift (model no. LM840CTPTMR, serial no. 041717653).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Bill Schoenecker Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343605523.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.