1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: U.S. MINERALS INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of U.S. MINERALS INC. in 11000 BALDWIN ROAD, BALDWIN, IL 62217 (NAICS 327910). OSHA activity number 343629143.

Watch U.S. Minerals INC. — free Get an email when a new federal OSHA severe-injury report for U.S. Minerals INC. is published. One employer, no account, unsubscribe in one click.
Establishment
U.S. MINERALS INC.
Site address
11000 BALDWIN ROAD
City
BALDWIN
State
IL
ZIP
62217
Mailing
18635 WEST CREEK DRIVE, TINLEY PARK, IL 60477
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327910
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.29 B02

Repeat Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11669.00 · Current $5835.00 Reduced
29 CFR 1910.29(b)(2): The employer did not ensure that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members were installed between the walking-working surface and the top edge of the guardrail system as follows when there was not a wall or parapet that was at least 21 inches (53 cm) high:    The employer did not ensure that a midrail, screen, mesh, intermediate vertical members, solid panels or equivalent intermediate members were installed on an approximately 8 foot high walking-working surface to protect employees from falling to a lower level.        U.S. Minerals LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.23(c)(1), which was contained in OSHA inspection number 918329, citation number 02, item number 01 and was affirmed as a final order on 09-08-2014, with respect to a workplace located at 11000 Baldwin Road, in Baldwin Illinois.
Recent events (2)
  • — I (R) $5835
  • — Z (R) $11669

1910.147 C04 II D

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control  The employer's written energy control procedures did not specifically identify how to test the wet plant conveyors to verify the effectiveness of a lockout device.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View U.S. MINERALS INC.'s full OSHA safety record →