Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: FOSTER GENERAL CONSTRUCTION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FOSTER GENERAL CONSTRUCTION in 437 700 ROAD, NEW OXFORD, PA 17350 (NAICS 238170). OSHA activity number 343689535.

Watch Foster General Construction — free Get an email when a new federal OSHA severe-injury report for Foster General Construction is published. One employer, no account, unsubscribe in one click.
Site address
437 700 ROAD
City
NEW OXFORD
State
PA
ZIP
17350
Mailing
38 APPLER COURT, LITTLESTOWN, PA 17340
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3500.00 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6):    (a)  437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold, and the ladder access to the West side of the scaffold plank where the employees accessed the scaffold was immediately adjacent to the unguarded electrical service connected to the house, on or about January 3, 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $3880

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2772.00 · Current $2000.00 Reduced
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.    (a)  437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold, and the West side of the scaffold plank extended over the West support approximately five feet, on or about January 3, 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2772

1926.451 F07

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1663.00 · Current $1000.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:    (a)  437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold at a height of approximately 20 feet, and the employees who erected the scaffold were not knowledgeable of basic scaffold erection and use requirements and strategies, on or about January 3, 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1663

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3880.00 · Current $3500.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a)  437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold at a height of approximately 20 feet, and the employees were not utilizing any type of fall protection,  on or about January 3, 2018.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.