NEW OXFORD, PA —
OSHA Inspection: FOSTER GENERAL CONSTRUCTION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FOSTER GENERAL CONSTRUCTION in 437 700 ROAD, NEW OXFORD, PA 17350 (NAICS 238170). OSHA activity number 343689535.
Where did this inspection happen?
- Establishment
- FOSTER GENERAL CONSTRUCTION
- Site address
- 437 700 ROAD
- City
- NEW OXFORD
- State
- PA
- ZIP
- 17350
- Mailing
- 38 APPLER COURT, LITTLESTOWN, PA 17340
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F06
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): (a) 437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold, and the ladder access to the West side of the scaffold plank where the employees accessed the scaffold was immediately adjacent to the unguarded electrical service connected to the house, on or about January 3, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3500
- — Z (S) $3880
1926.451 B05 II
- Issued
- Abate by
- Penalty
- Initial $2772.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. (a) 437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold, and the West side of the scaffold plank extended over the West support approximately five feet, on or about January 3, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2000
- — Z (S) $2772
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $1663.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: (a) 437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold at a height of approximately 20 feet, and the employees who erected the scaffold were not knowledgeable of basic scaffold erection and use requirements and strategies, on or about January 3, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1000
- — Z (S) $1663
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $3880.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: (a) 437 700 ROAD, NEW OXFORD, PA, NORTH SIDE - Employees performed soffit replacement work from a ladder jack scaffold at a height of approximately 20 feet, and the employees were not utilizing any type of fall protection, on or about January 3, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $3500
- — Z (S) $3880
More inspections in this industry (NAICS 238170)
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
WINSTON SALEM, NC—2026-07-09
161514 - ALPHA OMEGA CONSTRUCTION GROUP, INC
ATLANTA, GA—2026-07-09
ESV CONSTRUCTION LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343689535.