Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISE PLASTICS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRECISE PLASTICS, INC. in 7700 MIDDLE ROAD, FAIRVIEW, PA 16415 (NAICS 326199). OSHA activity number 343707410.

Watch Precise Plastics, INC. — free Get an email when a new federal OSHA severe-injury report for Precise Plastics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7700 MIDDLE ROAD
City
FAIRVIEW
State
PA
ZIP
16415
Mailing
7700 MIDDLE ROAD, FAIRVIEW, PA 16415
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
16
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3221.00 · Current $2000.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    A.)  Precise Plastics, Inc., 7700 Middle Road, Fairview, PA  16415, deflash room, on or about January 9, 2019 and times prior thereto:  Employees were potentially exposed to fire and explosion hazards from dust collectors located inside the building.  Dust collectors included, but not limited to, a DCE Vokes UMA152G5AD dust collector (S/N:  84-1854).    B.)  Precise Plastics, Inc., 7700 Middle Road, Fairview, PA  16415, deflash room, on or about January 9, 2019 and times prior thereto:  Employees were potentially exposed to fire and explosion hazards from dust collectors that were not equipped with devices and systems to prevent the propagation of explosions and associated flame fronts from the dust collector through the associated dust collection system ductwork.  Dust collection systems including, but not limited to, a DCE Vokes UMA152G5AD dust collector (S/N:  84-1854) was not equipped with approved devices to prevent the propagation of a dust explosion and associated flame fronts throughout the dust collection system and the associated ductwork.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3221

View PRECISE PLASTICS, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343707410.