Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MEDICO INDUSTRIES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MEDICO INDUSTRIES, INC. in 1500 HIGHWAY 315, WILKES BARRE, PA 18711 (NAICS 332995). OSHA activity number 343730586.

Watch Medico Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Medico Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1500 HIGHWAY 315
City
WILKES BARRE
State
PA
ZIP
18711
Mailing
1500 HIGHWAY 315, WILKES BARRE, PA 18711
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332995
Employees
275
Ownership type
A

4 citations on file for this inspection.

1910.95 G05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6440.00 · Current $4508.00 Reduced

Hazardous substances 8111

29 CFR 1910.95(g)(5)(i): The employer did not establish, within 6 months of an employee's first exposure at or above the action level, a valid baseline audiogram against which subsequent audiograms can be compared:  A) An employee, front department CNC machine operator, was exposed to continuous noise levels at 70.0% of the allowable eight (8)-hour time weighted sound level of 90 decibels (dBA).  The equivalent dBA level of 70.0% is approximately 92.1 dBA.  The sampling was performed for 165 minutes on February 6, 2019. (Zero exposure was assumed for the unsampled period of time.) A baseline audiogram was not established within six months of the employee's employment, on or about, February 6, 2019.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $4508
  • — Z (S) $6440

1910.95 G06

Serious Gravity 5 3 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 8111

29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels:    A) An employee, hydraulic forging press operator, was exposed to continuous noise levels at 68.3% of the allowable eight (8)-hour time weighted sound level of 90 decibels (dBA).  The equivalent dBA level of 68.3% is approximately 87.6 dBA.  The sampling was performed for 165 minutes on February 6, 2019. (Zero exposure was assumed for the unsampled period of time.) The employee's annual audiogram had not been obtained within the last calendar year, on or about, February 6, 2019.    B) An employee, roto blast operator, was exposed to continuous noise levels at 70.4% of the allowable eight (8)-hour time weighted sound level of 90 decibels (dBA).  The equivalent dBA level of 70.4% is approximately 92.7 dBA.  The sampling was performed for 163 minutes on February 6, 2019. (Zero exposure was assumed for the unsampled period of time.) The employee's annual audiogram had not been obtained within the last calendar year, on or about, February 6, 2019.    C) An employee, roto blast operator, was exposed to continuous noise levels at 72.5% of the allowable eight (8)-hour time weighted sound level of 90 decibels (dBA).  The equivalent dBA level of 72.5% is approximately 93.3 dBA.  The sampling was performed for 165 minutes on February 6, 2019. (Zero exposure was assumed for the unsampled period of time.) The employee's annual audiogram had not been obtained within the last calendar year, on or about, February 6, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 A

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances F117

29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:   a) Forge press operators were exposed to short duration flame during application of die lubricant and did not wear approved and rated fire resistant shirts and arm coverings, on or about, February 6, 2019.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.132 D01

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances F117

29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  A) Hydraulic forging press area, employees were exposed to burn hazards from short duration flame, and the Personal Protective Equipment Policy did not address the hazards and possible abatement methods available to employees, on or about, February 6, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View MEDICO INDUSTRIES, INC.'s full OSHA safety record →