DALLAS, GA —
OSHA Inspection: SUMTER UTILITIES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUMTER UTILITIES INC. in 5661 DALLAS HWY., DALLAS, GA 30132 (NAICS 238210). OSHA activity number 343772604.
Where did this inspection happen?
- Establishment
- SUMTER UTILITIES INC.
- Site address
- 5661 DALLAS HWY.
- City
- DALLAS
- State
- GA
- ZIP
- 30132
- Mailing
- 1151 N PIKE W, SUMTER, SC 29153
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.959 D03 III D
- Issued
- Abate by
- Penalty
- Initial $9472.00 · Current $9472.00
General-duty citation text
1926.959(d)(3)(iii)(D): Each employee was not protected from hazards that could arise from mechanical equipment contact with energized lines or equipment. Employing insulating protective equipment or barricades to guard against any remaining hazardous electrical potential differences. a) Worksite: On or about February 7, 2019, and at times prior, the employer exposed employees to electrical shock and burn hazards in that proper personal protective equipment was not provided while working near energized power lines.
Recent events (3)
- — F (O) $9472
- — C (S) $9472
- — Z (S) $9472
1926.1408 A02 III B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $9472.00
General-duty citation text
29 CFR 1926.1408(a)(2)(iii)(B): Determine if any part of the equipment, load line or load (including rigging and lifting accessories), while operating up to the equipment's maximum working radius in the work zone, could get closer than the minimum approach distance of the power line permitted under Table A (see �� 1926.1408). If so, then the employer must follow the requirements in paragraph (b) of this section to ensure that no part of the equipment, load line, or load (including rigging and lifting accessories), gets closer to the line than the minimum approach distance. (a) Worksite: On or about February 7, 2019, the employer exposed employees to electrical shock and burn hazards in that an Altec Telescopic Boom Truck Crane (Model AC45-127S Serial Number 0114FS0151) did not maintain a 10 foot clearance from the boom load line to energized 7,200 volts overhead power lines.
Recent events (3)
- — F (O) $9472
- — C (S) $0
- — Z (S) $0
More inspections at SUMTER UTILITIES INC.
BRANDYWINE, MD—2025-09-30
SUMTER UTILITIES, INC.
LAGRANGE, GA—2024-01-11 00:00:00
SUMTER UTILITIES INC.
MACON, GA—2023-09-21 00:00:00
SUMTER UTILITIES INC
CHARLESTON, SC—2013-05-21 00:00:00
SUMTER UTILITIES INC
SANTEE, SC—2012-05-24 00:00:00
SUMTER UTILITIES INC
View SUMTER UTILITIES INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source