1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SHOOK & FLETCHER INSULATION CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SHOOK & FLETCHER INSULATION CO. in 5320 FULTON INDUSTRIAL BLVD SW, ATLANTA, GA 30336 (NAICS 423810). OSHA activity number 343776951.

Watch Shook & Fletcher Insulation CO. — free Get an email when a new federal OSHA severe-injury report for Shook & Fletcher Insulation CO. is published. One employer, no account, unsubscribe in one click.
Site address
5320 FULTON INDUSTRIAL BLVD SW
City
ATLANTA
State
GA
ZIP
30336
Mailing
5320 FULTON INDUSTRIAL BLVD SW, ATLANTA, GA 30336
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423810
Employees
19
Ownership type
A

2 citations on file for this inspection.

1910.147 D04 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5304.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii): The procedures did not specifically outline the scope, purpose, authorization, rules and techniques to be utilized for the control of hazardous energy.     (a) Fabrication Shop: On February 4, 2019, the employer exposed employees to caught-in hazards in that a lockout or tagout device was not applied to the Bunting Company radius cutting band saw ("Saw #11") as authorized employees performed maintenance on the machine.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5304

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $5304.00 · Current $5304.00
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Fabrication Shop: On or about February 4, 2019, and at times prior, the employer exposed employees to caught-in hazards in that the belt drive of the Bunting Company radius cutting band saw ("Saw #11") was unguarded as employees performed maintenance on the machine.
Recent events (2)
  • — I (S) $5304
  • — Z (S) $5304

View SHOOK & FLETCHER INSULATION CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343776951.