FOSTORIA, OH —
OSHA Inspection: TREVES INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TREVES INC. in 615 NORTH CORPORATE DRIVE, FOSTORIA, OH 44830 (NAICS 336360). OSHA activity number 343961561.
Where did this inspection happen?
- Establishment
- TREVES INC.
- Site address
- 615 NORTH CORPORATE DRIVE
- City
- FOSTORIA
- State
- OH
- ZIP
- 44830
- Mailing
- 615 NORTH CORPORATE DRIVE, FOSTORIA, OH 44830
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336360
- Employees
- 52
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $13260.00 · Current $7956.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On April 23, 2019, the employer did not ensure that energy control procedures were developed, documented and utilized to control the energy sources when employees were performing maintenance tasks such as, but not limited to, checking and changing the oil in the Bush Rotary Vacuum Pump on top of thermal press #2. Employees were exposed to hazards such as, but not limited to burns while performing these tasks.
Recent events (2)
- — I (S) $7956
- — Z (S) $13260
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $13260.00 · Current $7956.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) On or about April 23, 2019, employees were exposed to injuries from moving parts and pressurized oil in that the thermal press #2 was not deenergized prior to performing servicing tasks such as, but not limited to, filling the Bush Vacuum Pump with oil. The employer did not ensure that energy control application steps were implemented to control the machine's hazardous energy sources prior to the performance of servicing tasks to include: � Ensure that equipment was turned off and shut down. � Physically engage energy isolating devices to control the energy source(s). � Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
- — I (S) $7956
- — Z (S) $13260
More inspections in this industry (NAICS 336360)
ROCHESTER HILLS, MI—2026-07-16
LEAR CORPORATION DBA EAGLE OTTAWA
HIGHLAND, MI—2026-07-07
DT MANUFACTURING COMPANY
IMLAY CITY, MI—2026-06-23
TOYO SEAT USA CORPORATION
HARPER WOODS, MI—2026-06-11
FISHER & COMPANY, INC DBA FISHER DYNAMICS
HARPER WOODS, MI—2026-05-15
FISHER & COMPANY, INC DBA FISHER DYNAMICS
More inspections in OH
WELLINGTON, OH—2026-07-16