Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: TREVES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TREVES INC. in 615 NORTH CORPORATE DRIVE, FOSTORIA, OH 44830 (NAICS 336360). OSHA activity number 343961561.

Watch Treves INC. — free Get an email when a new federal OSHA severe-injury report for Treves INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TREVES INC.
Site address
615 NORTH CORPORATE DRIVE
City
FOSTORIA
State
OH
ZIP
44830
Mailing
615 NORTH CORPORATE DRIVE, FOSTORIA, OH 44830
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336360
Employees
52
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $7956.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a)  On April 23, 2019, the employer did not ensure that energy control procedures were developed, documented and utilized to control the energy sources when employees were performing maintenance tasks such as, but not limited to, checking and changing the oil in the Bush Rotary Vacuum Pump on top of thermal press #2.   Employees were exposed to hazards such as, but not limited to burns while performing these tasks.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $7956.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    a) On or about April 23, 2019, employees were exposed to injuries from moving parts and pressurized oil in that the thermal press #2 was not deenergized prior to performing servicing tasks such as, but not limited to, filling the Bush Vacuum Pump with oil.  The employer did not ensure that energy control application steps were implemented to control the machine's hazardous energy sources prior to the performance of servicing tasks to include:      �  Ensure that equipment was turned off and shut down.      �  Physically engage energy isolating devices to control the energy source(s).       �  Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
  • — I (S) $7956
  • — Z (S) $13260

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343961561.