1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ALUMINUM COIL ANODIZING CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALUMINUM COIL ANODIZING CORPORATION in 501 E. LAKE STREET, STREAMWOOD, IL 60107 (NAICS 332813). OSHA activity number 344007505.

Watch Aluminum Coil Anodizing Corporation — free Get an email when a new federal OSHA severe-injury report for Aluminum Coil Anodizing Corporation is published. One employer, no account, unsubscribe in one click.
Site address
501 E. LAKE STREET
City
STREAMWOOD
State
IL
ZIP
60107
Mailing
501 E. LAKE STREET, STREAMWOOD, IL 60107
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
50
Ownership type
A

3 citations on file for this inspection.

1910.1026 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $3978.00 · Current $2500.00 Reduced

Hazardous substances 0689

29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):    a) On May 13, 2019, Aluminum Coil Anodizing Corporation did not determine the 8-hour time-weighted average exposure for an employee exposed to chromium (VI) while working in the laboratory.      No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3978

1910.1026 L02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2500.00 Reduced

Hazardous substances 0689

29 CFR 1910.1026(l)(2)(i): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to chromium (VI) were provided with information and training as required by the Hazard Communication standard, 29 CFR 1910.1200:     a) On May 13, 2019, Aluminum Coil Anodizing Corporation did not ensure that an employee exposed to chromium (VI) while working in the laboratory were provided information and training on chromium VI.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3978

1910.1200 F06 II

Serious Gravity 1 3 instances 12 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $2500.00 Reduced

Hazardous substances 0689

29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:    a) On May 23, 2019, on the anodizing lines, tanks containing sodium hydroxide (Etch); phosphoric acid, nitric acid, aluminum and dissolved copper (Bright Dip); phosphoric acid (Cleaner Tank and Dye); and sulfuric acid (Anodize) were not labeled with the name and the hazard warnings of the chemical contained therein.      b) On May 23, 2019, a large outdoor storage tank containing sulfuric acid (20% sulfuric acid, 80% water) was not labeled to identify the hazard of the chemical contained therein.      c) On May 23, 2019, in the laboratory, chromium VI solution stored in a 3-liter beaker, in the fume hood, was not labeled with the name and the hazard warnings of the chemical contained therein.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3978

View ALUMINUM COIL ANODIZING CORPORATION's full OSHA safety record →