ADDISON, PA —
OSHA Inspection: PRECISION PALLETS & LUMBER, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PRECISION PALLETS & LUMBER, LLC in 3593 LISTONBURG ROAD, ADDISON, PA 15411 (NAICS 321920). OSHA activity number 344232160.
Where did this inspection happen?
- Establishment
- PRECISION PALLETS & LUMBER, LLC
- Site address
- 3593 LISTONBURG ROAD
- City
- ADDISON
- State
- PA
- ZIP
- 15411
- Mailing
- 3593 LISTONBURG ROAD, ADDISON, PA 15411
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 20
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.95 C01
- Issued
- Abate by
- Penalty
- Initial $3410.00 · Current $2000.00 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level (TWA) of 85 dBA: a) In the Facility, on or about August 21, 2019 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA. An employee designated as a Nail Machine Operator was exposed to noise at a level of 74.5% of the allowable limit during a 300 minute sampling period on August 21, 2019. This exposure is equivalent to a sound level of 87.9 dBA for the dose and time of employee exposure and is 1.5 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required. b) In the Facility, on or about August 21, 2019 - An employee designated as a Nail Machine Operator was exposed to noise at a level of 86.3% of the allowable limit during a 302 minute sampling period on August 21, 2019. This exposure is equivalent to a sound level of 88.9 dBA for the dose and time of employee exposure and is 1.7 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required. c) In the Facility, on or about August 21, 2019 - An employee designated as a Stacker Operator was exposed to noise at a level of 93.7% of the allowable limit during a 303 minute sampling period on August 21, 2019. This exposure is equivalent to a sound level of 89.5 dBA for the dose and time of employee exposure and is 1.87 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required. d) In the Facility, on or about August 21, 2019 - An employee designated as a Hand Builder was exposed to noise at a level of 192.6% of the allowable limit during a 301 minute sampling period on August 21, 2019. This exposure is equivalent to a sound level of 94.7 dBA for the dose and time of employee exposure and is 3.9 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.
Recent events (2)
- — I (S) $2000
- — Z (S) $3410
1910.95 D01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) In the Facility, on or about August 21, 2019 - The employer did not develop and implement a noise monitoring program when employee's noise exposures equaled or exceeded the 8 hour time-weighted average of 85 decibels. (See descriptions of employee noise exposures in Citation 1, Item 1a, Instances a - d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : a) In the Facility, on or about August 21, 2019 - The employer did not obtain an annual audiometric test for employees whose are exposed to noise at or above an 8-hour time-weighted average of 85 decibels. (See descriptions of employee noise exposures in Citation 1, Item 1a, Instances a - d).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 L01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.95(l)(1): The employer did not make available to affected employees or their representatives copies of 29 CFR 1910.95 and did not post a copy in the workplace: a) In the Facility, on or about August 21, 2019 - The employer did not make a copy of 29 CFR 1910.95, the Occupational Noise Standard available to employees and post a copy in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3410.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) In the Facility, on or about August 14, 2019 - The employer did not establish and energy control program which consists of energy control procedures, employee training and periodic inspections. Employees at the facility utilize lockout for equipment including but not limited to gang saws, nailer machine and breaker panels.
Recent events (2)
- — I (S) $2000
- — Z (S) $3410
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) In the Facility, on or about August 14, 2019 - The employer did not develop and document energy control procedures at the facility. Employees at the facility utilize lockout for equipment including but not limited to gang saws, nailer machine and breaker panels.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) In the Facility, on or about August 14, 2019 - The employer did not provide training to employees on the purpose and function of the energy control procedures at the facility. Employees at the facility utilize lockout for equipment including but not limited to gang saws, nailer machine and breaker panels.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
8111
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a) In the Facility, on or about August 14, 2019 - The employer did not verify through a written certification that the required written personal protective equipment hazard assessment had been performed. Employees at the facility use personal protective equipment including but not limited to hearing protection, safety glasses and safety boots.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) In the Facility, on or about August 14, 2019 - The employer did not develop, implement and/or maintain a written hazard communication program at the facility. Employees work with hazardous materials including but not limited to oxygen and acetylene.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at PRECISION PALLETS & LUMBER, LLC
ADDISON, PA—2022-02-01 00:00:00
PRECISION PALLETS & LUMBER, LLC
View PRECISION PALLETS & LUMBER, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321920)
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
WASHINGTON COURT HOUSE, OH—2026-07-09
HALLIDAY LUMBER, LLC
HENDERSON, TX—2026-06-30
W.D. TOWNLEY AND SON LUMBER COMPANY, INC.
BOYCEVILLE, WI—2026-06-26
SPECIALTY MANUFACTURING OF MENOMONIE, LLC
JACKSONVILLE, FL—2026-06-25
CHEP SERVICES, LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344232160.