EAU CLAIRE, WI —
OSHA Inspection: GUNS AND HOSES ROOFING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUNS AND HOSES ROOFING in KEEGAN STREET LOT NO. 3, EAU CLAIRE, WI 54701 (NAICS 238160). OSHA activity number 344274535.
Where did this inspection happen?
- Establishment
- GUNS AND HOSES ROOFING
- Site address
- KEEGAN STREET LOT NO. 3
- City
- EAU CLAIRE
- State
- WI
- ZIP
- 54701
- Mailing
- 3987 40TH STREET, ELK MOUND, WI 54739
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 1
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2785.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Lot # 3, Keegan Street, Eau Claire, WI; Worker engaged in residential roofing from an unguarded roof greater than 6 feet above ground level was not utilizing adequate fall protection.
Recent events (2)
- — I (S) $2785
- — Z (S) $3978
1926.1053 B01
- Issued
- Penalty
- Initial $2273.00 · Current $1135.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet above the upper landing surface being accessed: (a) Lot # 3, Keegan Street, Eau Claire, WI; An extension ladder positioned on the West side of the residential structure for roof access did not extend at least 3 feet above the landing surface.
Recent events (2)
- — I (S) $1135
- — Z (S) $2273
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344274535.