OSHA Inspection: RICOH ELECTRONICS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RICOH ELECTRONICS, INC. in 1125 HURRICANE SHOALS ROAD, LAWRENCEVILLE, GA 30043 (NAICS 322220). OSHA activity number 344283098.

Watch Ricoh Electronics, INC. — free Get an email when a new federal OSHA severe-injury report for Ricoh Electronics, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1125 HURRICANE SHOALS ROAD
City
LAWRENCEVILLE
State
GA
ZIP
30043
Mailing
1125 HURRICANE SHOALS ROAD, LAWRENCEVILLE, GA 30043
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322220
Employees
625
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $7577.00 · Current $4546.00 Reduced

Hazardous substances E200

OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(l) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm, including severe burns, to employees in that employees were exposed to dust explosion, deflagration, or other fire hazards from dust collectors being located inside a building:    Ricoh Electronics, Inc., Lawrenceville, GA - The company had a Donaldson Torit dust collector system located in the thermal coating department, second floor, that collected combustible dust from the mixers, on or about 9/4/19.
Recent events (2)
  • — I (S) $4546.2
  • — Z (S) $7577

1910.1200 F06

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(f)(6): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either: (i) The information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or, (ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.  Ricoh Electronics, Inc., Lawrenceville, GA - In the thermal coating department, the employer did not ensure that each bag of hazardous chemicals in the workplace, such as but not limited to, BPS-44, BPS-24 and 2,4-Dihydroxydiphenyl sulfone, was labeled, tagged or marked as required, on or about 9/4/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 G08

Serious Gravity 1 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)  Ricoh Electronics, Inc., Lawrenceville, GA - In the thermal coating department, current safety data sheets for the products mixed were not maintained. The employer had MSDS's for products including, but not limited to, PBS-24, Bisphenol-S, and 2,4-Dihydroxydiphenyl sulfone 99%, on or about 9/4/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View RICOH ELECTRONICS, INC.'s full OSHA safety record →