HOUSTON, TX —
OSHA Inspection: PETROLEUM & GEOLOGY ENERGY, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PETROLEUM & GEOLOGY ENERGY, INC. in 3811 FUQUA STREET, HOUSTON, TX 77047 (NAICS 325199). OSHA activity number 344301486.
Where did this inspection happen?
- Establishment
- PETROLEUM & GEOLOGY ENERGY, INC.
- Site address
- 3811 FUQUA STREET
- City
- HOUSTON
- State
- TX
- ZIP
- 77047
- Mailing
- 10777 WESTHEIMER SUITE 1100, HOUSTON, TX 77042
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325199
- Employees
- 8
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2429.00 Reduced
041004202150B595
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to thermal hazards during the operation of a pyrolysis reactor unit. a) At the facility, batch pyrolysis reactor unit area: On or about August 30, 2019, employees operating gas return boiler metal ball valves were exposed to the hazard of thermal burns when valve levers were not installed properly to indicate correct operating position.
Recent events (2)
- — I (S) $2428.8
- — Z (S) $4048
1910.132 A
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2429.00 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: a) At the facility, batch tire pyrolysis unit area: On August 30, 2019, employees were exposed to thermal hazards when operating the rotary pyrolysis reactor without wearing fire retardant clothing (FRC).
Recent events (2)
- — I (S) $2428.8
- — Z (S) $4048
1910.219 D01
- Issued
- Abate by
- Penalty
- Initial $2892.00 · Current $1735.00 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) At the facility, batch tire pyrolysis unit area: On or about August 30, 2019 during initial start up and monitoring of a rotary pyrolysis reactor the belt drive pulleys were not guarded, presenting a caught-in hazard to employees.
Recent events (2)
- — I (S) $1735.2
- — Z (S) $2892
1910.219 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(e)(1): The horizontal belt seven feet or less from the floor level was not guarded: a) At the facility, batch tire pyrolysis unit area: On or about August 30, 2019 during initial start up and monitoring of a rotary pyrolysis reactor the belt drive was not guarded, presenting a caught-in hazard to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): a) At the facility, batch tire pyrolysis unit area: On or about August 30, 2019 during initial start up and monitoring of a rotary pyrolysis reactor the drive gears were not guarded, presenting a caught-in hazard to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Abate by
- Penalty
- Initial $4048.00 · Current $2429.00 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: a) At the facility, batch pyrolysis unit area: On or about August 30, 2019 electrical wiring, enclosures and connections installed to provide power to the batch pyrolysis unit were not safe for the hazardous location.
Recent events (2)
- — I (S) $2428.8
- — Z (S) $4048
More inspections at PETROLEUM & GEOLOGY ENERGY, INC.
HOUSTON, TX—2020-09-16 00:00:00
PETROLEUM & GEOLOGY ENERGY, INC.
View PETROLEUM & GEOLOGY ENERGY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325199)
HOPEWELL, VA—2026-06-17
ADVANSIX RESINS AND CHEMICALS LLC
GEORGETOWN, SC—2026-06-04
77516 - 3V SIGMA USA INC
CICERO, IL—2026-05-28
KOPPERS CARBON MATERIALS LLC
NARROWS, VA—2026-05-19
CELANESE ACETATE LLC
MARTINEZ, CA—2026-04-28
TESORO REFINING & MARKETING COMPANY LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344301486.