1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: ENVIRONMENTAL PRODUCTS & SERVICES OF VERMONT, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of ENVIRONMENTAL PRODUCTS & SERVICES OF VERMONT, INC. in 704 FRONT STREET, BINGHAMTON, NY 13905 (NAICS 562910). OSHA activity number 344326475.

Watch Environmental Products & Services OF Vermont, INC. — free Get an email when a new federal OSHA severe-injury report for Environmental Products & Services OF Vermont, INC. is published. One employer, no account, unsubscribe in one click.
Site address
704 FRONT STREET
City
BINGHAMTON
State
NY
ZIP
13905
Mailing
532 STATE FAIR BLVD, SYRACUSE, NY 13204
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
220
Ownership type
A

9 citations on file for this inspection.

1926.1204 C04

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1204(c)(4): Purging, inerting, flushing, or venting the confine space was not conducted by the employer as necessary to eliminate or control atmospheric hazards:  a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, Tank #2:  An employee was required to enter a 10,000 gallon gasoline storage tank, to clean and prepare it for removal,  The employer did not implement measures such as, but not limited to, forced air ventilation to eliminate the hazards of a flammable atmosphere, resulting in a deflagration and fire when an electric drill was used inside the permit required confined space.   Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1204 D01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1204(d)(1): The employer did not provide testing and monitoring equipment needed to comply with paragraph (e) of this section and ensure its use:    a) On or about 9/20/2019, 304 Front Street, Binghamton, NY Tank #1 and #2:  An employee was required to enter into 10,000 gallon gasoline storage tanks, to clean and prepare it for removal.  The employer did not provide monitoring equipment with the length of tubing necessary to access all strata of the space and ensure its use.     Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1204 D02

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1204(d)(2): The employer did not ensure that proper ventilation equipment was provided and used to obtain acceptable entry conditions:   a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, Tank #1:  An employee was required to enter a 10,000 gallon gasoline storage tank, to clean and prepare it for removal.  The employer did not provide and ensure the use of ventilating equipment such as, but not limited to, forced air ventilation to eliminate the hazard of a flammable atmosphere, resulting in a deflagration and fire when an electric drill was used inside the permit required confined space.    Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1204 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1204(e)(1): Permit confined space was not tested to determine if acceptable entry conditions existed before authorized entry was begun:  a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, tank #1:  An employee was required to enter a 10,000 gallon gasoline storage tank, to clean and prepare it for removal.  The employer did not ensure that the atmosphere inside this permit required confined space was tested prior to authorizing entry.     Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1204 E02

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1204(e)(2): Atmospheric hazards were not continuously monitored when equipment for continuous monitoring was commercially available:  a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, Tank #1:  Continuous atmospheric monitoring was not performed prior to and during entry into permit required confined spaces which had previously held a flammable liquid.  b) On or about 9/20/2019, 304 Front Street, Binghamton, NY, Tank #2:  Continuous atmospheric monitoring was not performed prior to and during entry into permit required confined spaces which had previously held a flammable liquid.  Abatement verification is required for these items.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1211 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1211(c)(2): A mechanical device was not available to retrieve employees from a confined space which was greater than five feet in depth:    a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, tanks #1 and #2:  No mechanical retrieval system was available while employees were in confined spaces which were eight feet in depth.    Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1211 C03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12145.00 · Current $12145.00
29 CFR 1926.1211(c)(3): Equipment unsuitable for retrieval was in use:     a) On or about 9/20/2019, 304 Front Street, Binghamton, NY, Tanks#1 and #2:  Synthetic rope was used as a retrieval rope in an environment where the rope could be exposed to heat and flames.    Abatement verification is required for this item.
Recent events (3)
  • — J (S) $12145
  • — C (S) $12145
  • — Z (S) $12145

1926.1210 B

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $119338.00 · Current $119338.00
29 CFR 1926.1210(b): The entry supervisor failed to verify, by checking that the appropriate entries have been made on the permit, that all tests specified by the permit have been conducted and that all procedures and equipment specified by the permit are in place before endorsing the permit and allowing entry to begin:  a) On or about 9/20/2019, 304 Front Street, Binghamton, NY:  The entry supervisor allowed an employee to enter a permit required confined space which had previously held a flammable liquid prior to verifying all of the permit items were filled out, all of the pre entry tests were conducted, and all of the equipment specified on the permit was in place.     Abatement verification is required for this item.
Recent events (3)
  • — J (S) $119338
  • — C (W) $119338
  • — Z (W) $119338

1926.1206 F

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1206(f): The entry permit did not identify each person serving as an attendant:  a) On or about 9/20/2019, 304 Front Street, Binghamton, NY:  There were two employees acting as an attendant during entry into the permit required confined space, and only one was identified on the permit.    Abatement verification is required for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View ENVIRONMENTAL PRODUCTS & SERVICES OF VERMONT, INC.'s full OSHA safety record →