NORTH KINGSTOWN, RI —
OSHA Inspection: AM ELECTRIC, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AM ELECTRIC, LLC in 426 SMITH STREET, NORTH KINGSTOWN, RI 02852 (NAICS 238210). OSHA activity number 344395769.
Where did this inspection happen?
- Establishment
- AM ELECTRIC, LLC
- Site address
- 426 SMITH STREET
- City
- NORTH KINGSTOWN
- State
- RI
- ZIP
- 02852
- Mailing
- 385 LINCOLN AVENUE, WARWICK, RI 02888
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 12
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Penalty
- Initial $5304.00 · Current $4000.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by injuries from a crane tip-over during a hoisting operation of metal poles, ranging from 20 to 30 feet in length, with the operator at the controls on the derrick. (a) Worksite: On or about 10/23/2019, the employer did not ensure that ground conditions were firm, drained and graded to accommodate the hoisting operation being performed by the Altec Digger Derrick, nor were any outrigger pads used to distribute the load weight over a larger area. (b) Worksite: On or about 10/23/2019, employees were exposed to tip-over type hazards from overloading the Altec Digger Derrick during the hoisting operation of five metal poles ranging from 20 to 30 feet in length.
Recent events (2)
- — I (S) $4000
- — Z (S) $5304
1910.135 A01
- Issued
- Penalty
- Initial $5304.00 · Current $2652.00 Reduced
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: (a) Worksite: On or about 10/23/2019, employees were exposed to struck-by type hazards from not wearing hardhats during a hoisting operation.
Recent events (2)
- — I (O) $2652
- — Z (S) $5304
1910.180 D06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for truck crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes: (a) Worksite: On or about 10/23/2019, the employer did not ensure that monthly inspections of the Altec Digger Derrick were performed and documented.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at AM ELECTRIC, LLC
SCITUATE, RI—2022-02-15 00:00:00
AM ELECTRIC, LLC
View AM ELECTRIC, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238210)
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
NIAGARA FALLS, NY—2026-07-10
GAINES ELECTRICAL CONTRACTING, INC.
OGDENSBURG, NY—2026-07-10
S & L ELECTRIC, INC.
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
LYNCHBURG, VA—2026-07-09
WHITE ELECTRICAL SERVICES LLC
More inspections in RI
NEWPORT, RI—2026-07-10
STEVEN POSTHUMA
MIDDLETOWN, RI—2026-07-10
GREENWOOD INDUSTRIES
JAMESTOWN, RI—2026-07-10
A K I CARPENTRY INC
NARRAGANSETT, RI—2026-07-09
ROGERS CORPORATION
WARWICK, RI—2026-07-09
LESLIE'S POOL SUPPLIES
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344395769.