SEGUIN, TX —
OSHA Inspection: GUNCKEL CUSTOM CABINETS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUNCKEL CUSTOM CABINETS INC. in 404 W. KINGSBURY, SEGUIN, TX 78155 (NAICS 337110). OSHA activity number 344446919.
Where did this inspection happen?
- Establishment
- GUNCKEL CUSTOM CABINETS INC.
- Site address
- 404 W. KINGSBURY
- City
- SEGUIN
- State
- TX
- ZIP
- 78155
- Mailing
- P.O. BOX 2400, SEGUIN, TX 78156
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 12
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $3031.00 · Current $1819.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: On or about November 14, 2019, and times prior thereto, the employer did not conduct an annual review of the energy control procedures. Employees exposed to the unexpected start-up of equipment.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.213 C01
- Issued
- Abate by
- Penalty
- Initial $3031.00 · Current $1819.00 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: On or about November 14, 2019, the Powermatic table saw did not have an automatic adjustable hood/guard. Employees use the table saw to rip boards for making cabinets. Employees exposed to an amputation hazard.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.213 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: On or about November 14, 2019, the Powermatic table saw did not have a spreader. Employees use the table saw to rip boards for making cabinets. Employees exposed to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: On or about November 14, 2019, the Powermatic table saw did not have a non kickback device. Employees use the table saw to rip boards for making cabinets. Employees exposed to being struck-by the board.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H01
- Issued
- Abate by
- Penalty
- Initial $3031.00 · Current $1819.00 Reduced
General-duty citation text
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock: On or about November 14, 2019, the Dewalt radial arm saw did not have a lower guard. Employees use the radial arm saw to cut wood for making cabinets. Employees were exposed to an amputation hazard.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
1910.303 F02
- Issued
- Abate by
- Penalty
- Initial $3031.00 · Current $1819.00 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about November 14, 2019, the 110 and 240 breaker boxes near the Powermatic table saw were not legibly marked to indicate the purpose. The breakers go to lights, receptacles and equipment. Employees exposed to delay of isolating the electrical source.
Recent events (2)
- — I (S) $1818.6
- — Z (S) $3031
More inspections in this industry (NAICS 337110)
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
EVERETT, WA—2026-06-29
WA317991850 - JMC CABINETS & INTERIORS INC
PUEBLO, CO—2026-06-26
WESTWIND WOOD SPECIALTIES INC.
BRAINERD, MN—2026-06-25
111484 - TRADITIONAL CABINETRY LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344446919.