Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRATHER PLUMBING AND HEATING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PRATHER PLUMBING AND HEATING, INC. in 528 S MAIN ST., MORTON, IL 61550 (NAICS 238220). OSHA activity number 344463104.

Watch Prather Plumbing AND Heating, INC. — free Get an email when a new federal OSHA severe-injury report for Prather Plumbing AND Heating, INC. is published. One employer, no account, unsubscribe in one click.
Site address
528 S MAIN ST.
City
MORTON
State
IL
ZIP
61550
Mailing
943 W CENTER STREET, EUREKA, IL 61530
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3181.00 · Current $2067.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    On or about November 21, 2019, an employee was exposed to crushing injuries associated with moving parts of an excavator bucket and fall hazards approximately 6 feet to the ground below when riding a Kubota Model KX 040-4 excavator bucket to exit an excavation 6 feet in depth.
Recent events (2)
  • — I (S) $2067
  • — Z (S) $3181

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2545.00 · Current $1655.00 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    On or about November 21, 2019, employees were exposed to struck by hazards while working below a Kubota Excavator removing material from an excavation and the employer did not ensure head protection was worn.
Recent events (2)
  • — I (S) $1655
  • — Z (S) $2545

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2545.00 · Current $1655.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    On or about November 21, 2019, employees were exposed to cave in hazards when entering an excavation six feet deep  and the employer did not ensure a means of egress was placed for employees to exit the excavation.
Recent events (2)
  • — I (S) $1655
  • — Z (S) $2545

1926.651 K01

Repeat Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5089.00 · Current $3309.00 Reduced
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by a competent person prior to the start of work and as needed throughout the shift:     On or about November 21, 2019, employees were exposed to cave in hazards when entering an excavation six feet deep and the employer did not ensure a competent person conducted an inspection of the excavation which included adequate protective system installation.    PRATHER PLUMBING & HEATING, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1926.652(k)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1168327, CITATION NUMBER 1, ITEM NUMBER 2, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 15, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT 9822 ALLEN ROAD, PEORIA, ILLINOIS 61615.
Recent events (2)
  • — I (R) $3309
  • — Z (R) $5089

1926.652 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $5089.00 · Current $3309.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):    On or about November 21, 2019, employees were exposed to cave in hazards when entering an excavation six feet deep and the employer did not ensure employees were protected with adequate sloping or a protective system.    PRATHER PLUMBING & HEATING, INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD 29 CFR 1926.652(a)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1168327, CITATION NUMBER 1, ITEM NUMBER 1b, AND WAS AFFIRMED AS A FINAL ORDER ON SEPTEMBER 15, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT 9822 ALLEN ROAD, PEORIA, ILLINOIS 61615.
Recent events (2)
  • — I (R) $3309
  • — Z (R) $5089

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344463104.