HAMMOND, WI —
OSHA Inspection: GUY METALS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GUY METALS, INC. in 1890 GUY METALS DRIVE, HAMMOND, WI 54015 (NAICS 423510). OSHA activity number 344523295.
Where did this inspection happen?
- Establishment
- GUY METALS, INC.
- Site address
- 1890 GUY METALS DRIVE
- City
- HAMMOND
- State
- WI
- ZIP
- 54015
- Mailing
- 1890 GUY METALS DRIVE, HAMMOND, WI 54015
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 70
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $7422.00 · Current $4450.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Throughout the production area; The employer did not conduct periodic inspections of the machine specific energy control procedures on at least an annual basis.
Recent events (2)
- — I (S) $4450
- — Z (S) $7422
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $7422.00 · Current $2975.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) Northwest production area, compressed gas cylinder storage location; A full compressed oxygen cylinder was stored within 4 feet from two full acetylene cylinders.
Recent events (2)
- — I (S) $2975
- — Z (S) $7422
1910.333 B02 III A
- Issued
- Abate by
- Penalty
- Initial $7422.00 · Current $4450.00 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag was not placed on each disconnecting means used to deenergize circuits and equipment on which work is to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section: (a) North production area; IMEAS No. 1; On or about December 18, 2019, an employee opened the motor control center (MCC) for IMEAS No. 1 to reset a hydraulic thermal switch without affixing a lock and tag to the electrical disconnect.
Recent events (2)
- — I (S) $4450
- — Z (S) $7422
1910.303 E
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary: (a) North production area; Motor control centers (MCCs) for IMEAS No. 1, IMEAS No. 2 and IMEAS No. 3 were not provided with markings to indicate electrical equipment voltage, current, wattage, and other necessary ratings.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GUY METALS, INC.
HAMMOND, WI—2016-02-11 00:00:00
GUY METALS INC
HAMMOND, WI—2014-05-07 00:00:00
GUY METALS INC
View GUY METALS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423510)
HAMMOND, IN—2026-07-07
JUPITER ALUMINUM CORPORATION
BETTENDORF, IA—2026-07-06
A09CS000011UWT9AAA - OLYMPIC STEEL, INC.
GREELEY, CO—2026-07-01
NORFOLK IRON & METAL COMPANY
OAKLAND, CA—2026-06-30
TAV HOLDINGS, INC.
HOUSTON, TX—2026-06-29
SEOJIN GLOBAL INC.
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.