TUCSON, AZ —
OSHA Inspection: U.S. DEPARTMENT OF VETERANS AFFAIRS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. DEPARTMENT OF VETERANS AFFAIRS in ATTN: JOHN LI (1-08 ENG) 3601 SOUTH 6TH AVENUE, TUCSON, AZ 85723 (NAICS 622110). OSHA activity number 344653795.
Where did this inspection happen?
- Establishment
- U.S. DEPARTMENT OF VETERANS AFFAIRS
- Site address
- ATTN: JOHN LI (1-08 ENG) 3601 SOUTH 6TH AVENUE
- City
- TUCSON
- State
- AZ
- ZIP
- 85723
- Mailing
- SOUTHERN ARIZONA VA HEALTH CARE SYSTEM 3601 SOUTH 6TH AVENUE, TUCSON, AZ 85723
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 2845
- Ownership type
- D
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) BUILDING 43: The Porter Cable Drill Press SN-063243 was not guarded to protect employees from contact with the rotating bit, exposing them to caught-in hazards. (b) BOILER ROOM: The Rockwell Drill Press SN-1784343 was not guarded to protect employees from contact with the rotating bit, exposing them to caught-in hazards.
Recent events (1)
- — Z (S) $0
1910.303 G01 I B
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater : (a) BUILDING 43: The electrical panel was blocked by an portable air exchanger and a tool box exposing employees to fire and electrocution hazards.
Recent events (1)
- — Z (S) $0
1910.303 G01 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less. BUILDING 44: The main disconnect panel was blocked by cactus preventing access to the panel in the event of an emergency, exposing employees to electrocution, burn, and smoke inhalation hazards.
Recent events (1)
- — Z (S) $0
1910.104 B08 VIII
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.104(b)(8)(viii): "Placarding." The bulk oxygen storage location shall be permanently placarded to indicate: "OXYGEN - NO SMOKING - NO OPEN FLAMES", or an equivalent warning. 29 CFR 1910.104(b)(8)(viii): "Placarding." The bulk oxygen storage location shall be permanently placarded to indicate: "OXYGEN - NO SMOKING - NO OPEN FLAMES", or an equivalent warning. 29 CFR 1910.104(b)(8)(viii): "Placarding." The bulk oxygen storage location shall be permanently placarded to indicate: "OXYGEN - NO SMOKING - NO OPEN FLAMES", or an equivalent warning. ROOM A148: Signs had not been posted to make employees aware of the location and dangers associated oxygen storage, exposing them to hazards from fires.
Recent events (1)
- — Z (O) $0
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: BUILDING 14 WAREHOUSE: The Hyster H70FT forklift was not examined before being placed in use exposing employees to injury from defects.
Recent events (1)
- — Z (O) $0
More inspections at U.S. DEPARTMENT OF VETERANS AFFAIRS
COLUMBIA, SC—2026-07-02
U.S. DEPARTMENT OF VETERANS AFFAIRS
ORLANDO, FL—2026-07-01
U.S. DEPARTMENT OF VETERANS AFFAIRS
JASPER, GA—2026-03-19
U.S. DEPARTMENT OF VETERANS AFFAIRS
DECATUR, GA—2026-02-06
U.S. DEPARTMENT OF VETERANS AFFAIRS
MARTINSBURG, WV—2026-01-14
U.S. DEPARTMENT OF VETERANS AFFAIRS
View U.S. DEPARTMENT OF VETERANS AFFAIRS's full OSHA safety record →
More inspections in this industry (NAICS 622110)
SAN JUAN, PR—2026-07-15
MUNICIPIO DE SAN JUAN
RIO PIEDRAS, PR—2026-07-15
CFSE
NORWALK, CA—2026-07-10
CPH HOSPITAL MANAGEMENT LLC
ANTIOCH, CA—2026-07-10
SUTTER DELTA MEDICAL CENTER
BURBANK, CA—2026-07-07
PROVIDENCE SAINT JOSEPH HOSPITAL
More inspections in AZ
CHANDLER, AZ—2026-07-16
SUN STATE BUILDERS
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
CAMP VERDE, AZ—2026-07-14
CLIFF CASTLE CASINO & HOTEL
TUCSON, AZ—2026-07-10
CPX2026XJL680X0074 - JANC EXCAVATING AND CONSTRUCTION, LLC
Source