Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SIMCOE WOOD PRODUCTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SIMCOE WOOD PRODUCTS, INC. in 3730 AL HWY 69 N, CULLMAN, AL 35058 (NAICS 321920). OSHA activity number 344664040.

Watch Simcoe Wood Products, INC. — free Get an email when a new federal OSHA severe-injury report for Simcoe Wood Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3730 AL HWY 69 N
City
CULLMAN
State
AL
ZIP
35058
Mailing
3730 AL HWY 69 N, CULLMAN, AL 35058
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
44
Ownership type
A

4 citations on file for this inspection.

1910.169 B03 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8906.00 · Current $6030.00 Reduced
29 CFR 1910.169(b)(3)(iii): Safety appliances such as safety valves, indicating devices and controlling devices, were not constructed, located, and/or installed so that they could not be readily rendered inoperative by any means, including the elements:    (a) On or about 02/06/2020 - Whirlwind Cut-Off Saw Area, employees who operated the a Whirlwind Model 212L Cut-Off Saw Model 212L, Serial #N5025048L were exposed to amputation hazards because the air pressure gauge was half-full of sawdust and rendered inoperative thereby reducing the effectiveness of the guard.
Recent events (2)
  • — I (S) $6030
  • — Z (S) $8906

1910.213 R04

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $10390.00 · Current $6030.00 Reduced
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of Whirlwind Model 212L Cut-Off Saw:     (a) On or about 02/06/2020 - Whirlwind Cut-Off Saw Area, employees who operated the a Whirlwind Model 212L Cut-Off Saw Model 212L, Serial #N5025048L were exposed to amputation hazards because the Proximity/Work Presence Sensor for the guard was missing thereby reducing the effectiveness of the guard.
Recent events (2)
  • — I (S) $6030
  • — Z (S) $10390

1910.213 S06

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8906.00 · Current $6030.00 Reduced
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:    (a) On or about 02/13/2020 - Whirlwind Cut-Off Saw Area, employees were exposed to electrical shock and fire hazards because the power cord on the Whirlwind Cut-Off Saw, Model 212L, Serial #N5025048L was pulled from its fitting at the back of the saw, and the exposed wires and electrical connections were coated with sawdust.
Recent events (2)
  • — I (S) $6030
  • — Z (S) $8906

1910.265 C20 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $8906.00 · Current $6030.00 Reduced
29 CFR 1910.265(c)(20)(ii): Machine(s) that created dust, shavings, chips, or slivers during a period of time equal to or greater than one-fourth of the working day were not equipped with collecting system(s)    (a) On or about 02/06/2020 - Whirlwind Cut-Off Saw Area, employees were exposed to fire hazards because the Whirlwind Cut-Off Saw, Model 212L, Serial #N5025048L created sawdust at least 25% of the working day and was not equipped with collecting system(s) causing internal machine components including exposed wires and electrical connections to be coated with sawdust.
Recent events (2)
  • — I (S) $6030
  • — Z (S) $8906

View SIMCOE WOOD PRODUCTS, INC.'s full OSHA safety record →